Skip to content
OpenTrain AIFor AI Companies

Can Agentic Systems Close the Gap in Radiology with Production AI Tools?

Aubin Charley, Julien Khlaut, Charles Corbière, Pierre Manceron, Corentin Dancette +1 morePublished Nov 6, 2026
arXiv PDF
Researcher verdict
Context only
Use as context only
Benchmark evidence
Missing
Not verified yet
Time to first repro
A few days
Plan setup time
Risk flags
2
Review before use

No concrete benchmark grounding is available yet. Treat the page as context or an implementation starting point only.

Abstract

Domain fit: AI-adjacent · Paper appears method- or tooling-adjacent to AI workflows with partial ecosystem coverage.

Radiology AI has developed along two paths: specialized models that perform well on narrow tasks but cover few clinical findings, and generalist models that address a broader range of tasks but remain prone to hallucination and inaccurate measurements. Combining the two through agentic systems offers a route towards comprehensive radiology reporting, but published systems are tied to one modality or body part. We describe a radiology agentic framework that standardizes how an orchestrator calls modular tools to produce a structured report, and use it to measure what such a system can do with the tools from FDA-cleared radiology AI devices. Report generation is simulated on a large multi-modality report corpus, with the orchestrator given either a catalog of finding classes consolidated from the cleared devices, each available on the modalities it is cleared for, or an unlimited catalog in which any class can be requested, and planning either from the clinical indication or from the target report. Tool outputs are simulated from the reference report, so the comparison isolates tool availability and orchestration from tool error. With the cleared catalog and the indication alone, the orchestrator recovers under a third of the clinically actionable findings; recovery improves substantially with the unlimited catalog, and further when the plan is written from the target report. Attributing every missed finding to a cause shows that most are classes no cleared device offers for the study's modality, and that a third are classes or tools that were offered and not called. Adding the most frequently missing tools closes most of the gap to the unlimited catalog on held-out reports, whereas a smaller orchestrator with the unlimited catalog gives up the whole gain. Tool availability and effective orchestration are thus complementary constraints on comprehensive AI-assisted radiology reporting.

Results and benchmarks

Radiology AI has developed along two paths: specialized models that perform well on narrow tasks but cover few clinical findings, and generalist models that address a broader range of tasks but remain prone to hallucination and inaccurate measurements.

Implementation

No direct implementation yet

Maintained implementation evidence is not confirmed for this paper yet.

Use the implementation status and reproduction sections for the current action plan.

Implementation evidence summary
Confidence: low

Recommendation evidence is currently too limited for a maintained-repo choice. Use Implementation Status and Reproduction Path for a practical baseline plan.

Reproduction risks
  • Estimate is based on paper-only reproduction flow

Reproduction readiness

Time to first repro: days
Last checked: Nov 24, 2026

No repo

No verified implementation available

  • No maintained repository has been identified for this paper. Check adjacent implementations or HF artifacts below.

Hardware requirements

  • Expect multi-day setup/compute for meaningful reproduction based on current guidance.

Repositories and ecosystem

No additional verified repositories beyond the primary recommendation.

Hugging Face artifacts

No trustworthy direct or curated related Hugging Face artifacts were found yet. Use targeted searches to quickly locate candidate models, datasets, and demos.

Tip: start with models, then check datasets and spaces if you need evaluation data or demos.

Research context

Tasks

Agentic tool use

Methods

Agentic systems

Domains

AI Agents

Evaluation and human feedback data

Open this paper in HFEPX to review benchmark signals, evaluation modes, and human-feedback protocol context.

Open in HFEPX
Explore similar papers

Jump to Paper2Code search queries derived from this paper's research context.