Auditable Clinical Support with Decision Agents
Abstract
Domain fit: AI-adjacent · Paper appears method- or tooling-adjacent to AI workflows with partial ecosystem coverage.
Clinicians reviewing a diagnostic work-up will ask what was considered at each step and why the assessment changed. Agents powered by free text can reach physician-level diagnostic accuracy, but their written reasoning does not always reflect the factors that went into the decision. Here, we present Decision2Care, a decision agent that works up the acutely ill patient without producing any text. A decision model assigns a probability to each permitted EHR action, and fixed rules carry out the most probable one. We evaluated Decision2Care on the records of 546 emergency admissions across 12 diseases. Decision2Care reached a diagnostic accuracy of 86.5%, compared with 86.1% for the MIRA-v2 agent, and required a median of 2.2 s per work-up, compared with 92-100 s. Each work-up tracked which options Decision2Care was considering at each step. In 10 of the 12 diseases, the differential diagnosis changed most at the test on which the guideline bases the diagnosis. Where Decision2Care was most confident after a single work-up, all but four of its diagnoses were correct (98.5%). We traced each of these four errors back to a single imaging report. Three of them were corrected when that report was removed. The same kind of decision was used to select the treatments, and Decision2Care's drug orders were judged guideline-adherent more often than MIRA-v2's. In emergency patients, its prediction of death was comparable to that of three intensivists on the same cases. In five of the eight intensive care cohorts, it exceeded the best of the three 24-h severity scores within 2-6 h of records. Our results show that decision agents can carry out clinical work-ups while recording the options, probabilities, and execution rules behind each action for audit.
Results and benchmarks
Clinicians reviewing a diagnostic work-up will ask what was considered at each step and why the assessment changed.
Benchmark evidence is limited
Evidence graph: 2 refs, 1 links.
Utility signals: depth 95/100, grounding 68/100, status medium.
Implementation
No direct implementation yet
Maintained implementation evidence is not confirmed for this paper yet.
Use the implementation status and reproduction sections for the current action plan.
No verified maintained repo yet
There is no verified maintained implementation yet. Use this baseline plan to decide whether to prototype now or defer.
- No direct maintained implementation was found. Use the paper PDF and citation graph to design a baseline reproduction.
- Track assumptions and missing details in an experiment log before coding.
Time to first repro: a few days
Recommendation evidence is currently too limited for a maintained-repo choice. Use Implementation Status and Reproduction Path for a practical baseline plan.
- Estimate is based on paper-only reproduction flow
Reproduction readiness
No repo
No verified implementation available
- No maintained repository has been identified for this paper. Check adjacent implementations or HF artifacts below.
Hardware requirements
- Expect multi-day setup/compute for meaningful reproduction based on current guidance.
Hugging Face artifacts
No trustworthy direct or curated related Hugging Face artifacts were found yet. Use targeted searches to quickly locate candidate models, datasets, and demos.
Models
Datasets
Spaces
Tip: start with models, then check datasets and spaces if you need evaluation data or demos.
Research context
Tasks
Agentic tool use
Methods
Agentic systems
Domains
AI Agents
Open this paper in HFEPX to review benchmark signals, evaluation modes, and human-feedback protocol context.
Open in HFEPXJump to Paper2Code search queries derived from this paper's research context.