Skip to content
OpenTrain AIFor AI Companies

HFEPX · Eval paper review

CardioVascBench:Prioritized Diagnosis Generation from Real-World Chinese Cardiovascular Records

Minghao Kong, Muyao Chen, Jianhao Wu, Yuqiang Zhang +6 more

Published

Nov 3, 2026

Citations

0

Trust level

Moderate

Usefulness score

65/100 (Medium)

Extraction confidence

70% (Moderate)

Derived from extracted protocol signals and abstract evidence.

Rater population

Domain Experts

Signals refreshed

Nov 3, 2026

Should you rely on this paper?

This paper has useful evaluation signal, but protocol completeness is partial; pair it with related papers before deciding implementation strategy.

Use this for comparison and orientation, not as your only source.

Best use

Secondary protocol comparison source

Use if you need

A secondary eval reference to pair with stronger protocol papers.

What to verify

Validate the evaluation procedure and quality controls in the full paper before operational use.

Main weakness

No major weakness surfaced.

Human feedback signal
Detected
From extracted signals
Evaluation signal
Detected
Eval setup described
Usefulness for eval research
65/100
Moderate-confidence candidate

Useful as a secondary reference; validate protocol details against neighboring papers.

Abstract

Identifying the primary diagnosis alone does not fully characterize a model's diagnosis-generation performance. We introduce CardioVascBench, a retrospective benchmark for prioritized diagnosis generation from real-world Chinese cardiovascular inpatient records. It contains 3,262 de-identified cases, with 2,174 for training and 1,088 for evaluation, linking clinical narratives and textual ECG reports to expert-verified, ordered discharge diagnoses standardized to ICD-10. An English translation of the evaluation set supports aligned cross-lingual comparison. Our evaluation protocol combines terminology normalization and rank-aware scoring to separately assess primary-diagnosis identification, reference-diagnosis coverage, and list precision. Evaluation across 36 systems shows that higher primary-diagnosis accuracy does not necessarily imply higher list precision against discharge references. We also provide CardioKG-Agent, a knowledge-enhanced baseline combining entity normalization, constrained graph retrieval, and guideline evidence. In a staged comparison of three baseline models, supervised fine-tuning plus the agent achieves a 73.5% higher mean composite score than fine-tuning alone, representing a system-level gain. These results measure retrospective agreement with recorded diagnoses; agreement between metric rankings and physician judgments remains to be validated. CardioVascBench supports research on diagnosis prioritization and knowledge-enhanced generation.

What we could verify

These are the protocol signals we could actually recover from the available paper metadata. Use them to decide whether this paper is worth deeper reading.

Human Feedback Types

strong

Expert Verification

Directly usable for protocol triage.

"Identifying the primary diagnosis alone does not fully characterize a model's diagnosis-generation performance."

Evaluation Modes

strong

Automatic Metrics

Includes extracted eval setup.

"Identifying the primary diagnosis alone does not fully characterize a model's diagnosis-generation performance."

Quality Controls

missing

Not reported

No explicit QC controls found.

"Identifying the primary diagnosis alone does not fully characterize a model's diagnosis-generation performance."

Benchmarks / Datasets

missing

Not extracted

No benchmark anchors detected.

"Identifying the primary diagnosis alone does not fully characterize a model's diagnosis-generation performance."

Reported Metrics

strong

Accuracy

Useful for evaluation criteria comparison.

"Evaluation across 36 systems shows that higher primary-diagnosis accuracy does not necessarily imply higher list precision against discharge references."

Rater Population

strong

Domain Experts

Helpful for staffing comparability.

"It contains 3,262 de-identified cases, with 2,174 for training and 1,088 for evaluation, linking clinical narratives and textual ECG reports to expert-verified, ordered discharge diagnoses standardized to ICD-10."

Benchmarks and datasets

No benchmark or dataset names were extracted from the available abstract.

Reported metrics

accuracy
Human feedback details
Uses human feedback
Yes
Feedback types
Expert Verification
Rater population
Domain Experts
Expertise required
Medicine, Multilingual
Evaluation details
Evaluation modes
Automatic Metrics
Agentic eval
None
Quality controls
Not reported
Evidence quality
Moderate
Use this page as
Secondary protocol comparison source

Research brief

Metadata summary

Identifying the primary diagnosis alone does not fully characterize a model's diagnosis-generation performance.

Based on abstract + metadata only. Check the source paper before making high-confidence protocol decisions.

Key takeaways

  • Identifying the primary diagnosis alone does not fully characterize a model's diagnosis-generation performance.
  • We introduce CardioVascBench, a retrospective benchmark for prioritized diagnosis generation from real-world Chinese cardiovascular inpatient records.
  • It contains 3,262 de-identified cases, with 2,174 for training and 1,088 for evaluation, linking clinical narratives and textual ECG reports to expert-verified, ordered discharge diagnoses standardized to ICD-10.

Researcher actions

  • Compare this paper against nearby papers in the same arXiv category before using it for protocol decisions.
  • Validate inferred eval signals (Automatic metrics) against the full paper.
  • Use related-paper links to find stronger protocol-specific references.

Caveats

  • Generated from abstract + metadata only; no PDF parsing.
  • Signals below are heuristic and may miss details reported outside the abstract.

Contribution summary

  • Identifying the primary diagnosis alone does not fully characterize a model's diagnosis-generation performance.
  • We introduce CardioVascBench, a retrospective benchmark for prioritized diagnosis generation from real-world Chinese cardiovascular inpatient records.

Why it matters for eval

  • It contains 3,262 de-identified cases, with 2,174 for training and 1,088 for evaluation, linking clinical narratives and textual ECG reports to expert-verified, ordered discharge diagnoses standardized to ICD-10.

Researcher checklist

  • Human feedback protocol is explicit

    Detected: Expert Verification

  • Evaluation mode is explicit

    Detected: Automatic Metrics

  • Quality control reporting appears

    No calibration/adjudication/IAA control explicitly detected.

  • Benchmark or dataset anchors are present

    No benchmark/dataset anchor extracted from abstract.

  • Metric reporting is present

    Detected: accuracy