Human Feedback Types
strongExpert Verification
Directly usable for protocol triage.
"Identifying the primary diagnosis alone does not fully characterize a model's diagnosis-generation performance."
HFEPX · Eval paper review
Minghao Kong, Muyao Chen, Jianhao Wu, Yuqiang Zhang +6 more
Published
Nov 3, 2026
Citations
0
Trust level
Moderate
Usefulness score
65/100 (Medium)
Extraction confidence
70% (Moderate)
Derived from extracted protocol signals and abstract evidence.
Rater population
Domain Experts
Signals refreshed
Nov 3, 2026
This paper has useful evaluation signal, but protocol completeness is partial; pair it with related papers before deciding implementation strategy.
Use this for comparison and orientation, not as your only source.
Best use
Secondary protocol comparison source
Use if you need
A secondary eval reference to pair with stronger protocol papers.
What to verify
Validate the evaluation procedure and quality controls in the full paper before operational use.
Main weakness
No major weakness surfaced.
Useful as a secondary reference; validate protocol details against neighboring papers.
If you are doing eval pipeline work, start here
Identifying the primary diagnosis alone does not fully characterize a model's diagnosis-generation performance. We introduce CardioVascBench, a retrospective benchmark for prioritized diagnosis generation from real-world Chinese cardiovascular inpatient records. It contains 3,262 de-identified cases, with 2,174 for training and 1,088 for evaluation, linking clinical narratives and textual ECG reports to expert-verified, ordered discharge diagnoses standardized to ICD-10. An English translation of the evaluation set supports aligned cross-lingual comparison. Our evaluation protocol combines terminology normalization and rank-aware scoring to separately assess primary-diagnosis identification, reference-diagnosis coverage, and list precision. Evaluation across 36 systems shows that higher primary-diagnosis accuracy does not necessarily imply higher list precision against discharge references. We also provide CardioKG-Agent, a knowledge-enhanced baseline combining entity normalization, constrained graph retrieval, and guideline evidence. In a staged comparison of three baseline models, supervised fine-tuning plus the agent achieves a 73.5% higher mean composite score than fine-tuning alone, representing a system-level gain. These results measure retrospective agreement with recorded diagnoses; agreement between metric rankings and physician judgments remains to be validated. CardioVascBench supports research on diagnosis prioritization and knowledge-enhanced generation.
These are the protocol signals we could actually recover from the available paper metadata. Use them to decide whether this paper is worth deeper reading.
Expert Verification
Directly usable for protocol triage.
"Identifying the primary diagnosis alone does not fully characterize a model's diagnosis-generation performance."
Automatic Metrics
Includes extracted eval setup.
"Identifying the primary diagnosis alone does not fully characterize a model's diagnosis-generation performance."
Not reported
No explicit QC controls found.
"Identifying the primary diagnosis alone does not fully characterize a model's diagnosis-generation performance."
Not extracted
No benchmark anchors detected.
"Identifying the primary diagnosis alone does not fully characterize a model's diagnosis-generation performance."
Accuracy
Useful for evaluation criteria comparison.
"Evaluation across 36 systems shows that higher primary-diagnosis accuracy does not necessarily imply higher list precision against discharge references."
Domain Experts
Helpful for staffing comparability.
"It contains 3,262 de-identified cases, with 2,174 for training and 1,088 for evaluation, linking clinical narratives and textual ECG reports to expert-verified, ordered discharge diagnoses standardized to ICD-10."
No benchmark or dataset names were extracted from the available abstract.
Identifying the primary diagnosis alone does not fully characterize a model's diagnosis-generation performance.
Based on abstract + metadata only. Check the source paper before making high-confidence protocol decisions.
Human feedback protocol is explicit
Detected: Expert Verification
Evaluation mode is explicit
Detected: Automatic Metrics
Quality control reporting appears
No calibration/adjudication/IAA control explicitly detected.
Benchmark or dataset anchors are present
No benchmark/dataset anchor extracted from abstract.
Metric reporting is present
Detected: accuracy