Safety and accuracy follow different scaling laws in clinical large language models
Sebastian Wind, Tri-Thien Nguyen, Jeta Sopa, Mahshad Lotfinia, Sebastian Bickelhaup, Michael Uder, Harald Köstler, Gerhard Wellein, Sven Nebelung, Daniel Truhn, Andreas Maier, Soroosh Tayebi Arasteh · May 5, 2026 · Citations: 0
How to use this page
Moderate trustUse this for comparison and orientation, not as your only source.
Best use
Secondary protocol comparison source
What to verify
Validate the evaluation procedure and quality controls in the full paper before operational use.
Evidence quality
Moderate
Derived from extracted protocol signals and abstract evidence.
Abstract
Clinical LLMs are often scaled by increasing model size, context length, retrieval complexity, or inference-time compute, with the implicit expectation that higher accuracy implies safer behavior. This assumption is incomplete in medicine, where a few confident, high-risk, or evidence-contradicting errors can matter more than average benchmark performance. We introduce SaFE-Scale, a framework for measuring how clinical LLM safety changes across model scale, evidence quality, retrieval strategy, context exposure, and inference-time compute. To instantiate this framework, we introduce RadSaFE-200, a Radiology Safety-Focused Evaluation benchmark of 200 multiple-choice questions with clinician-defined clean evidence, conflict evidence, and option-level labels for high-risk error, unsafe answer, and evidence contradiction. We evaluated 34 locally deployed LLMs across six deployment conditions: closed-book prompting (zero-shot), clean evidence, conflict evidence, standard RAG, agentic RAG, and max-context prompting. Clean evidence produced the strongest improvement, increasing mean accuracy from 73.5% to 94.1%, while reducing high-risk error from 12.0% to 2.6%, contradiction from 12.7% to 2.3%, and dangerous overconfidence from 8.0% to 1.6%. Standard RAG and agentic RAG did not reproduce this safety profile: agentic RAG improved accuracy over standard RAG and reduced contradiction, but high-risk error and dangerous overconfidence remained elevated. Max-context prompting increased latency without closing the safety gap, and additional inference-time compute produced only limited gains. Worst-case analysis showed that clinically consequential errors concentrated in a small subset of questions. Clinical LLM safety is therefore not a passive consequence of scaling, but a deployment property shaped by evidence quality, retrieval design, context construction, and collective failure behavior.