Skip to content
OpenTrain AIFor AI Companies

HFEPX · Eval paper review

Call-Efficient ICD-10 Code Prediction via Supervised Candidate Generation and Selective LLM Invocation

Ilia Kopanichuk, Daniil Kartashev, Yuri Bolkonsky, Petr Anokhin +3 more

Published

Nov 16, 2026

Citations

0

Trust level

Low

Usefulness score

0/100 (Low)

Extraction confidence

35% (Low)

Derived from extracted protocol signals and abstract evidence.

Rater population

Not reported

Signals refreshed

Nov 16, 2026

Should you rely on this paper?

This paper is adjacent to HFEPX scope and is best used for background context, not as a primary protocol reference.

Use this as background context only. Do not make protocol decisions from this page alone.

Best use

Background context only

Use if you need

A secondary eval reference to pair with stronger protocol papers.

What to verify

Validate the evaluation procedure and quality controls in the full paper before operational use.

Main weakness

This paper looks adjacent to evaluation work, but not like a strong protocol reference.

Human feedback signal
Not explicit
Not explicit in abstract metadata
Evaluation signal
Detected
Eval setup described
Usefulness for eval research
0/100
Adjacent candidate

Treat as adjacent context, not a core eval-method reference.

Abstract

Automatic assignment of ICD-10 codes from short clinical diagnosis text is a practical medical text classification and normalization task. The task is difficult because diagnosis phrases are short and noisy, the ICD-10 label space is hierarchical, and the class distribution is strongly imbalanced. This paper presents a call-efficient ICD-10 code prediction pipeline that combines transformer embeddings, tree-based supervised candidate generation, candidate-level reranking, and a gated LLM assistance. The evaluation uses a leakage-safe validation protocol: model and threshold selection are based on out-of-fold cross-validation predictions, while final reporting is performed on a locked test set with no shared source-file groups. The supervised conditional parent-code candidate generator reaches 74.32% Top-1 accuracy on the locked test set and 93.05% Top-10 candidate coverage. A direct zero-shot GPT-5.6-Sol baseline reaches 81.01% Top-1 accuracy, but requires an invocation of this large model for every diagnosis. The final deployable system, Pre-LLM fusion, reaches 81.24% OOF-CV accuracy and 83.19% locked-test accuracy while calling the LLM for only 31.97% of cases. This improves the locked-test error rate from 25.68% for the supervised parent-code baseline to 16.81%, corresponding to a 34.5% relative error reduction. The results show that the most effective role of the LLM is controlled reranking on uncertain examples rather than unrestricted coding or full-dataset invocation.

What we could verify

These are the protocol signals we could actually recover from the available paper metadata. Use them to decide whether this paper is worth deeper reading.

Human Feedback Types

missing

None explicit

No explicit feedback protocol extracted.

"Automatic assignment of ICD-10 codes from short clinical diagnosis text is a practical medical text classification and normalization task."

Evaluation Modes

partial

Automatic Metrics

Includes extracted eval setup.

"Automatic assignment of ICD-10 codes from short clinical diagnosis text is a practical medical text classification and normalization task."

Quality Controls

missing

Not reported

No explicit QC controls found.

"Automatic assignment of ICD-10 codes from short clinical diagnosis text is a practical medical text classification and normalization task."

Benchmarks / Datasets

missing

Not extracted

No benchmark anchors detected.

"Automatic assignment of ICD-10 codes from short clinical diagnosis text is a practical medical text classification and normalization task."

Reported Metrics

partial

Accuracy

Useful for evaluation criteria comparison.

"The supervised conditional parent-code candidate generator reaches 74.32% Top-1 accuracy on the locked test set and 93.05% Top-10 candidate coverage."

Benchmarks and datasets

No benchmark or dataset names were extracted from the available abstract.

Reported metrics

accuracy
Human feedback details
Uses human feedback
No
Feedback types
None
Rater population
Not reported
Expertise required
Medicine, Coding
Evaluation details
Evaluation modes
Automatic Metrics
Agentic eval
None
Quality controls
Not reported
Evidence quality
Low
Use this page as
Background context only

Research brief

Metadata summary

Automatic assignment of ICD-10 codes from short clinical diagnosis text is a practical medical text classification and normalization task.

Based on abstract + metadata only. Check the source paper before making high-confidence protocol decisions.

Key takeaways

  • Automatic assignment of ICD-10 codes from short clinical diagnosis text is a practical medical text classification and normalization task.
  • The task is difficult because diagnosis phrases are short and noisy, the ICD-10 label space is hierarchical, and the class distribution is strongly imbalanced.
  • This paper presents a call-efficient ICD-10 code prediction pipeline that combines transformer embeddings, tree-based supervised candidate generation, candidate-level reranking, and a gated LLM assistance.

Researcher actions

  • Compare this paper against nearby papers in the same arXiv category before using it for protocol decisions.
  • Validate inferred eval signals (Automatic metrics) against the full paper.
  • Use related-paper links to find stronger protocol-specific references.

Caveats

  • Generated from abstract + metadata only; no PDF parsing.
  • Signals below are heuristic and may miss details reported outside the abstract.

Recommended queries

Contribution summary

  • Automatic assignment of ICD-10 codes from short clinical diagnosis text is a practical medical text classification and normalization task.
  • The task is difficult because diagnosis phrases are short and noisy, the ICD-10 label space is hierarchical, and the class distribution is strongly imbalanced.

Why it matters for eval

  • The evaluation uses a leakage-safe validation protocol: model and threshold selection are based on out-of-fold cross-validation predictions, while final reporting is performed on a locked test set with no shared source-file groups.

Researcher checklist

  • Human feedback protocol is explicit

    No explicit human feedback protocol detected.

  • Evaluation mode is explicit

    Detected: Automatic Metrics

  • Quality control reporting appears

    No calibration/adjudication/IAA control explicitly detected.

  • Benchmark or dataset anchors are present

    No benchmark/dataset anchor extracted from abstract.

  • Metric reporting is present

    Detected: accuracy