Skip to content
OpenTrain AIFor AI Companies

HFEPX · Eval paper review

Clinician Assessment of Laryngeal Disease with Auditory AI before Laryngoscopy: A Paired Reader Study

Siyuan Hou, Shuting Yang, Zengrui Jin, Liyu Cheng +12 more

Published

Nov 15, 2026

Citations

0

Trust level

Moderate

Usefulness score

65/100 (Medium)

Extraction confidence

70% (Moderate)

Derived from extracted protocol signals and abstract evidence.

Rater population

Domain Experts

Signals refreshed

Nov 15, 2026

Should you rely on this paper?

This paper has useful evaluation signal, but protocol completeness is partial; pair it with related papers before deciding implementation strategy.

Use this for comparison and orientation, not as your only source.

Best use

Secondary protocol comparison source

Use if you need

A secondary eval reference to pair with stronger protocol papers.

What to verify

Validate the evaluation procedure and quality controls in the full paper before operational use.

Main weakness

No major weakness surfaced.

Human feedback signal
Detected
From extracted signals
Evaluation signal
Detected
Eval setup described
Usefulness for eval research
65/100
Moderate-confidence candidate

Useful as a secondary reference; validate protocol details against neighboring papers.

Abstract

Background: Before laryngoscopy, clinicians assess the likely cause of hoarseness and whether to suspect a precancerous or malignant lesion. Whether voice-based artificial intelligence (AI) supports pre-laryngoscopic categorization is unknown. Methods: We developed an auditory large language model that generates a patient-level assessment card (provisional category, voice-quality ratings, and rationale) and a prespecified malignancy alert from voice recordings, patient information, and acoustic measures obtained before laryngoscopy at one center. We evaluated both in a held-out test set and a later cohort. In a sequential reader study, 32 otolaryngology clinicians categorized held-out cases without AI and, 1 to 2 weeks later, reviewed their initial categories with the card (without the alert). Results: Across 800 paired assessments, reader accuracy was 49.8% before and 56.8% after review (difference, 7.0 percentage points; 95% CI, 1.7 to 13.5; P < 0.001); 99 categories changed from incorrect to correct and 43 from correct to incorrect (ratio, 2.30; 95% CI, 1.22 to 5.31). Accuracy rose 14.7 points when the model was correct and fell 8.7 when incorrect. Provisional-category accuracy was 72% in held-out testing and 67% in temporal validation. The malignancy alert flagged 85.7% and 86.8% of precancerous or malignant lesions. Sensitivity for precancerous or malignant lesions increased from 53.9% to 75.0% after AI-assisted review (difference, 21.1 percentage points; 95% CI, 4.3 to 42.0). Conclusions: In this single-center study, clinicians' pre-laryngoscopic categorization accuracy was higher after reviewing the AI assessment card, although the sequential design cannot fully separate AI assistance from reassessment; gains depended on model correctness without clearly selective adoption. Randomized and external evaluations, including of the malignancy alert, are needed.

What we could verify

These are the protocol signals we could actually recover from the available paper metadata. Use them to decide whether this paper is worth deeper reading.

Human Feedback Types

strong

Expert Verification

Directly usable for protocol triage.

"Background: Before laryngoscopy, clinicians assess the likely cause of hoarseness and whether to suspect a precancerous or malignant lesion."

Evaluation Modes

strong

Automatic Metrics

Includes extracted eval setup.

"Background: Before laryngoscopy, clinicians assess the likely cause of hoarseness and whether to suspect a precancerous or malignant lesion."

Quality Controls

missing

Not reported

No explicit QC controls found.

"Background: Before laryngoscopy, clinicians assess the likely cause of hoarseness and whether to suspect a precancerous or malignant lesion."

Benchmarks / Datasets

missing

Not extracted

No benchmark anchors detected.

"Background: Before laryngoscopy, clinicians assess the likely cause of hoarseness and whether to suspect a precancerous or malignant lesion."

Reported Metrics

strong

Accuracy

Useful for evaluation criteria comparison.

"Results: Across 800 paired assessments, reader accuracy was 49.8% before and 56.8% after review (difference, 7.0 percentage points; 95% CI, 1.7 to 13.5; P < 0.001); 99 categories changed from incorrect to correct and 43 from correct to incorrect (ratio, 2.30; 95% CI, 1.22 to 5.31)."

Rater Population

strong

Domain Experts

Helpful for staffing comparability.

"Background: Before laryngoscopy, clinicians assess the likely cause of hoarseness and whether to suspect a precancerous or malignant lesion."

Benchmarks and datasets

No benchmark or dataset names were extracted from the available abstract.

Reported metrics

accuracy
Human feedback details
Uses human feedback
Yes
Feedback types
Expert Verification
Rater population
Domain Experts
Expertise required
Medicine
Evaluation details
Evaluation modes
Automatic Metrics
Agentic eval
None
Quality controls
Not reported
Evidence quality
Moderate
Use this page as
Secondary protocol comparison source

Research brief

Metadata summary

Background: Before laryngoscopy, clinicians assess the likely cause of hoarseness and whether to suspect a precancerous or malignant lesion.

Based on abstract + metadata only. Check the source paper before making high-confidence protocol decisions.

Key takeaways

  • Background: Before laryngoscopy, clinicians assess the likely cause of hoarseness and whether to suspect a precancerous or malignant lesion.
  • Whether voice-based artificial intelligence (AI) supports pre-laryngoscopic categorization is unknown.
  • Methods: We developed an auditory large language model that generates a patient-level assessment card (provisional category, voice-quality ratings, and rationale) and a prespecified malignancy alert from voice recordings, patient information, and acoustic measures obtained before laryngoscopy at one center.

Researcher actions

  • Compare this paper against nearby papers in the same arXiv category before using it for protocol decisions.
  • Validate inferred eval signals (Automatic metrics) against the full paper.
  • Use related-paper links to find stronger protocol-specific references.

Caveats

  • Generated from abstract + metadata only; no PDF parsing.
  • Signals below are heuristic and may miss details reported outside the abstract.

Recommended queries

Contribution summary

  • Background: Before laryngoscopy, clinicians assess the likely cause of hoarseness and whether to suspect a precancerous or malignant lesion.
  • Whether voice-based artificial intelligence (AI) supports pre-laryngoscopic categorization is unknown.

Why it matters for eval

  • We evaluated both in a held-out test set and a later cohort.

Researcher checklist

  • Human feedback protocol is explicit

    Detected: Expert Verification

  • Evaluation mode is explicit

    Detected: Automatic Metrics

  • Quality control reporting appears

    No calibration/adjudication/IAA control explicitly detected.

  • Benchmark or dataset anchors are present

    No benchmark/dataset anchor extracted from abstract.

  • Metric reporting is present

    Detected: accuracy