Human Feedback Types
strongExpert Verification
Directly usable for protocol triage.
"Background: Before laryngoscopy, clinicians assess the likely cause of hoarseness and whether to suspect a precancerous or malignant lesion."
HFEPX · Eval paper review
Siyuan Hou, Shuting Yang, Zengrui Jin, Liyu Cheng +12 more
Published
Nov 15, 2026
Citations
0
Trust level
Moderate
Usefulness score
65/100 (Medium)
Extraction confidence
70% (Moderate)
Derived from extracted protocol signals and abstract evidence.
Rater population
Domain Experts
Signals refreshed
Nov 15, 2026
This paper has useful evaluation signal, but protocol completeness is partial; pair it with related papers before deciding implementation strategy.
Use this for comparison and orientation, not as your only source.
Best use
Secondary protocol comparison source
Use if you need
A secondary eval reference to pair with stronger protocol papers.
What to verify
Validate the evaluation procedure and quality controls in the full paper before operational use.
Main weakness
No major weakness surfaced.
Useful as a secondary reference; validate protocol details against neighboring papers.
If you are doing eval pipeline work, start here
Background: Before laryngoscopy, clinicians assess the likely cause of hoarseness and whether to suspect a precancerous or malignant lesion. Whether voice-based artificial intelligence (AI) supports pre-laryngoscopic categorization is unknown. Methods: We developed an auditory large language model that generates a patient-level assessment card (provisional category, voice-quality ratings, and rationale) and a prespecified malignancy alert from voice recordings, patient information, and acoustic measures obtained before laryngoscopy at one center. We evaluated both in a held-out test set and a later cohort. In a sequential reader study, 32 otolaryngology clinicians categorized held-out cases without AI and, 1 to 2 weeks later, reviewed their initial categories with the card (without the alert). Results: Across 800 paired assessments, reader accuracy was 49.8% before and 56.8% after review (difference, 7.0 percentage points; 95% CI, 1.7 to 13.5; P < 0.001); 99 categories changed from incorrect to correct and 43 from correct to incorrect (ratio, 2.30; 95% CI, 1.22 to 5.31). Accuracy rose 14.7 points when the model was correct and fell 8.7 when incorrect. Provisional-category accuracy was 72% in held-out testing and 67% in temporal validation. The malignancy alert flagged 85.7% and 86.8% of precancerous or malignant lesions. Sensitivity for precancerous or malignant lesions increased from 53.9% to 75.0% after AI-assisted review (difference, 21.1 percentage points; 95% CI, 4.3 to 42.0). Conclusions: In this single-center study, clinicians' pre-laryngoscopic categorization accuracy was higher after reviewing the AI assessment card, although the sequential design cannot fully separate AI assistance from reassessment; gains depended on model correctness without clearly selective adoption. Randomized and external evaluations, including of the malignancy alert, are needed.
These are the protocol signals we could actually recover from the available paper metadata. Use them to decide whether this paper is worth deeper reading.
Expert Verification
Directly usable for protocol triage.
"Background: Before laryngoscopy, clinicians assess the likely cause of hoarseness and whether to suspect a precancerous or malignant lesion."
Automatic Metrics
Includes extracted eval setup.
"Background: Before laryngoscopy, clinicians assess the likely cause of hoarseness and whether to suspect a precancerous or malignant lesion."
Not reported
No explicit QC controls found.
"Background: Before laryngoscopy, clinicians assess the likely cause of hoarseness and whether to suspect a precancerous or malignant lesion."
Not extracted
No benchmark anchors detected.
"Background: Before laryngoscopy, clinicians assess the likely cause of hoarseness and whether to suspect a precancerous or malignant lesion."
Accuracy
Useful for evaluation criteria comparison.
"Results: Across 800 paired assessments, reader accuracy was 49.8% before and 56.8% after review (difference, 7.0 percentage points; 95% CI, 1.7 to 13.5; P < 0.001); 99 categories changed from incorrect to correct and 43 from correct to incorrect (ratio, 2.30; 95% CI, 1.22 to 5.31)."
Domain Experts
Helpful for staffing comparability.
"Background: Before laryngoscopy, clinicians assess the likely cause of hoarseness and whether to suspect a precancerous or malignant lesion."
No benchmark or dataset names were extracted from the available abstract.
Background: Before laryngoscopy, clinicians assess the likely cause of hoarseness and whether to suspect a precancerous or malignant lesion.
Based on abstract + metadata only. Check the source paper before making high-confidence protocol decisions.
Human feedback protocol is explicit
Detected: Expert Verification
Evaluation mode is explicit
Detected: Automatic Metrics
Quality control reporting appears
No calibration/adjudication/IAA control explicitly detected.
Benchmark or dataset anchors are present
No benchmark/dataset anchor extracted from abstract.
Metric reporting is present
Detected: accuracy