Skip to content
OpenTrain AIFor AI Companies

HFEPX · Eval paper review

Excess Separability: Nuisance-Controlled Residual-Stream Probing for Benchmark Contamination Detection

Florian Braun

Published

Aug 12, 2026

Citations

0

Trust level

Moderate

Usefulness score

65/100 (Medium)

Extraction confidence

70% (Moderate)

Derived from extracted protocol signals and abstract evidence.

Rater population

Not reported

Signals refreshed

Aug 12, 2026

Should you rely on this paper?

This paper has useful evaluation signal, but protocol completeness is partial; pair it with related papers before deciding implementation strategy.

Use this for comparison and orientation, not as your only source.

Best use

Secondary protocol comparison source

Use if you need

A secondary eval reference to pair with stronger protocol papers.

What to verify

Validate the evaluation procedure and quality controls in the full paper before operational use.

Main weakness

No major weakness surfaced.

Human feedback signal
Detected
From extracted signals
Evaluation signal
Detected
Eval setup described
Usefulness for eval research
65/100
Moderate-confidence candidate

Useful as a secondary reference; validate protocol details against neighboring papers.

Abstract

Benchmark contamination is diagnosed today with n-gram overlap, with likelihood-based membership inference, or with canary strings, and each needs something usually unavailable: the training corpus, a well-chosen test statistic, or foresight at dataset release. A recent alternative reads contamination off a linear probe on internal activations. We show that the natural way to do this does not work, and specify one that survives measurement. The protocol reports a zero-sum contrast on the depth profile of probe accuracy, recentred on a level-matched placebo baseline, tested against a label-permutation null, with the reference set twice the size of the suspect set. Each choice replaces a simpler alternative we measured and rejected. Reporting the level of excess separability rather than its shape makes the false positive rate track the size of the analyst's own control set, from 0.03 to 0.99 under a true null. Contrasting against a flat depth profile fails in both directions, rejecting a true null 0.72 of the time when surface decodability rises with depth and losing all power when it falls. An item bootstrap holds the fitted probe fixed and rejects up to 0.09 of the time where a permutation null that refits it holds 0.02. A half-size baseline triples the error rate. On real transformers, baseline depth profiles are measurably not flat, spanning up to 29.1 accuracy points on a temporal split, and their non-flatness tracks the surface difference between the item sets (correlation 0.87 over 6 audits), so the correction is largest exactly where it is needed. All 4 well-matched Pile arms return null, and the protocol refuses a verdict on the temporal split rather than reporting one. What this does not establish is whether transformers carry a familiarity direction at all: the only positive sits on the split where exchangeability fails. Implementation, tests and audits are released.

What we could verify

These are the protocol signals we could actually recover from the available paper metadata. Use them to decide whether this paper is worth deeper reading.

Human Feedback Types

strong

Pairwise Preference

Directly usable for protocol triage.

"Benchmark contamination is diagnosed today with n-gram overlap, with likelihood-based membership inference, or with canary strings, and each needs something usually unavailable: the training corpus, a well-chosen test statistic, or foresight at dataset release."

Evaluation Modes

strong

Automatic Metrics

Includes extracted eval setup.

"Benchmark contamination is diagnosed today with n-gram overlap, with likelihood-based membership inference, or with canary strings, and each needs something usually unavailable: the training corpus, a well-chosen test statistic, or foresight at dataset release."

Quality Controls

missing

Not reported

No explicit QC controls found.

"Benchmark contamination is diagnosed today with n-gram overlap, with likelihood-based membership inference, or with canary strings, and each needs something usually unavailable: the training corpus, a well-chosen test statistic, or foresight at dataset release."

Benchmarks / Datasets

missing

Not extracted

No benchmark anchors detected.

"Benchmark contamination is diagnosed today with n-gram overlap, with likelihood-based membership inference, or with canary strings, and each needs something usually unavailable: the training corpus, a well-chosen test statistic, or foresight at dataset release."

Reported Metrics

strong

Accuracy, Error rate

Useful for evaluation criteria comparison.

"The protocol reports a zero-sum contrast on the depth profile of probe accuracy, recentred on a level-matched placebo baseline, tested against a label-permutation null, with the reference set twice the size of the suspect set."

Benchmarks and datasets

No benchmark or dataset names were extracted from the available abstract.

Reported metrics

accuracyerror rate
Human feedback details
Uses human feedback
Yes
Feedback types
Pairwise Preference
Rater population
Not reported
Unit of annotation
Pairwise
Expertise required
General
Evaluation details
Evaluation modes
Automatic Metrics
Agentic eval
None
Quality controls
Not reported
Evidence quality
Moderate
Use this page as
Secondary protocol comparison source

Research brief

Metadata summary

Benchmark contamination is diagnosed today with n-gram overlap, with likelihood-based membership inference, or with canary strings, and each needs something usually unavailable: the training corpus, a well-chosen test statistic, or foresight at dataset release.

Based on abstract + metadata only. Check the source paper before making high-confidence protocol decisions.

Key takeaways

  • Benchmark contamination is diagnosed today with n-gram overlap, with likelihood-based membership inference, or with canary strings, and each needs something usually unavailable: the training corpus, a well-chosen test statistic, or foresight at dataset release.
  • A recent alternative reads contamination off a linear probe on internal activations.
  • We show that the natural way to do this does not work, and specify one that survives measurement.

Researcher actions

  • Compare this paper against nearby papers in the same arXiv category before using it for protocol decisions.
  • Validate inferred eval signals (Automatic metrics) against the full paper.
  • Use related-paper links to find stronger protocol-specific references.

Caveats

  • Generated from abstract + metadata only; no PDF parsing.
  • Signals below are heuristic and may miss details reported outside the abstract.

Recommended queries

Contribution summary

  • Benchmark contamination is diagnosed today with n-gram overlap, with likelihood-based membership inference, or with canary strings, and each needs something usually unavailable: the training corpus, a well-chosen test statistic, or…
  • We show that the natural way to do this does not work, and specify one that survives measurement.
  • The protocol reports a zero-sum contrast on the depth profile of probe accuracy, recentred on a level-matched placebo baseline, tested against a label-permutation null, with the reference set twice the size of the suspect set.

Why it matters for eval

  • Benchmark contamination is diagnosed today with n-gram overlap, with likelihood-based membership inference, or with canary strings, and each needs something usually unavailable: the training corpus, a well-chosen test statistic, or…

Researcher checklist

  • Human feedback protocol is explicit

    Detected: Pairwise Preference

  • Evaluation mode is explicit

    Detected: Automatic Metrics

  • Quality control reporting appears

    No calibration/adjudication/IAA control explicitly detected.

  • Benchmark or dataset anchors are present

    No benchmark/dataset anchor extracted from abstract.

  • Metric reporting is present

    Detected: accuracy, error rate