Human Feedback Types
missingNone explicit
No explicit feedback protocol extracted.
"Changes in illumination can induce action drift in dexterous manipulation even when the physical state remains unchanged."
HFEPX · Eval paper review
Xudi Ge, Yepeng Liu, Haifeng Liu, Enze Shi +2 more
Published
Nov 19, 2026
Citations
0
Trust level
Low
Usefulness score
0/100 (Low)
Extraction confidence
15% (Low)
Derived from extracted protocol signals and abstract evidence.
Rater population
Not reported
Signals refreshed
Nov 19, 2026
This paper is adjacent to HFEPX scope and is best used for background context, not as a primary protocol reference.
Use this as background context only. Do not make protocol decisions from this page alone.
All signals on this page are inferred from the abstract only and may be inaccurate. Do not use this page as a primary protocol reference.
Best use
Background context only
Use if you need
Background context only.
What to verify
Read the full paper before copying any benchmark, metric, or protocol choices.
Main weakness
This paper looks adjacent to evaluation work, but not like a strong protocol reference.
Treat as adjacent context, not a core eval-method reference.
If you are doing eval pipeline work, start here
Changes in illumination can induce action drift in dexterous manipulation even when the physical state remains unchanged. Although existing vision--tactile--language--action (VTLA) policies incorporate tactile feedback, when and how touch refines actions under changing visual conditions remains challenging. We introduce \textbf{TipDex-VTLA}, a VTLA policy that combines estimated visual action reliability and tactile forecast verification to regulate execution-time refinement. Specifically, Visual Action Sensitivity Estimation (VASE) learns visual reliability from a frozen reference policy's action sensitivity to illumination perturbations. Tactile Anticipation and Correction during Execution (TACE) compares predicted and measured touch at matched times and combines the resulting discrepancy with visual reliability to gate bounded feature corrections for unexecuted actions. This effectively helps to refine actions under challenging unseen visual conditions. We evaluate TipDex-VTLA on four real-world dexterous manipulation tasks and the UniVTAC simulation benchmark. TipDex-VTLA trained on data collected under normal visual conditions, achieves average full-task success rates of 87.5% (resp. 73.8%) under normal (resp. challenging unseen) lighting in real-world tasks, significantly outperforming some state-of-the-art methods. We will release the collected data and source code.
These are the protocol signals we could actually recover from the available paper metadata. Use them to decide whether this paper is worth deeper reading.
None explicit
No explicit feedback protocol extracted.
"Changes in illumination can induce action drift in dexterous manipulation even when the physical state remains unchanged."
None explicit
Validate eval design from full paper text.
"Changes in illumination can induce action drift in dexterous manipulation even when the physical state remains unchanged."
Not reported
No explicit QC controls found.
"Changes in illumination can induce action drift in dexterous manipulation even when the physical state remains unchanged."
Not extracted
No benchmark anchors detected.
"Changes in illumination can induce action drift in dexterous manipulation even when the physical state remains unchanged."
Not extracted
No metric anchors detected.
"Changes in illumination can induce action drift in dexterous manipulation even when the physical state remains unchanged."
No benchmark or dataset names were extracted from the available abstract.
No metric terms were extracted from the available abstract.
Changes in illumination can induce action drift in dexterous manipulation even when the physical state remains unchanged.
Based on abstract + metadata only. Check the source paper before making high-confidence protocol decisions.
Human feedback protocol is explicit
No explicit human feedback protocol detected.
Evaluation mode is explicit
No clear evaluation mode extracted.
Quality control reporting appears
No calibration/adjudication/IAA control explicitly detected.
Benchmark or dataset anchors are present
No benchmark/dataset anchor extracted from abstract.
Metric reporting is present
No metric terms extracted.