Human Feedback Types
missingNone explicit
No explicit feedback protocol extracted.
"A digital twin of a patient in intensive care would forecast the patient's course and what a treatment would change."
HFEPX · Eval paper review
Zhuoyang Lyu, Yiming Li, Peter C. Hou, Pengyu Hong +1 more
Published
Nov 23, 2026
Citations
0
Trust level
Low
Usefulness score
25/100 (Low)
Extraction confidence
45% (Low)
Derived from extracted protocol signals and abstract evidence.
Rater population
Not reported
Signals refreshed
Nov 23, 2026
This paper is adjacent to HFEPX scope and is best used for background context, not as a primary protocol reference.
Use this as background context only. Do not make protocol decisions from this page alone.
Use this page for context, then validate protocol choices against stronger HFEPX references before implementation decisions.
Best use
Background context only
Use if you need
A secondary eval reference to pair with stronger protocol papers.
What to verify
Validate the evaluation procedure and quality controls in the full paper before operational use.
Main weakness
The available metadata is too thin to trust this as a primary source.
Treat as adjacent context, not a core eval-method reference.
If you are doing eval pipeline work, start here
A digital twin of a patient in intensive care would forecast the patient's course and what a treatment would change. Generative event models, trained to continue a patient's electronic health record (EHR), have been proposed as a path toward such twins. We trained TWICE, a 79M-parameter decoder-only transformer, on the ICU records of one academic health system (127,332 training patients and 1.57 billion tokens). We evaluated it on clinical prediction tasks, generation fidelity, individual trajectories and counterfactual validation. Reading 19 clinical outcomes off 50 simulated futures, with no task-specific training, TWICE matched the best of 144 supervised configurations on held-out patients (mean AUROC 0.836 vs. 0.834). It led on events that change care within a day and trailed on death. With the training data fixed, more and longer simulated futures were worth more than a 6.8-fold larger model. Its generated records matched real ones closely and were as specific to each patient as its own variability allowed. Its predicted risk rose as events approached. Pre-specified controls showed that it reproduced the side effects of drugs and was barely moved by an inert drug. On the values that treatments are given to correct, however, an opposite treatment moved its forecasts like the right one. TWICE forecasts ICU events about as well as task-specific models, and we see it as a step toward a digital twin of the ICU patient.
These are the protocol signals we could actually recover from the available paper metadata. Use them to decide whether this paper is worth deeper reading.
None explicit
No explicit feedback protocol extracted.
"A digital twin of a patient in intensive care would forecast the patient's course and what a treatment would change."
Automatic Metrics
Includes extracted eval setup.
"A digital twin of a patient in intensive care would forecast the patient's course and what a treatment would change."
Not reported
No explicit QC controls found.
"A digital twin of a patient in intensive care would forecast the patient's course and what a treatment would change."
Not extracted
No benchmark anchors detected.
"A digital twin of a patient in intensive care would forecast the patient's course and what a treatment would change."
Auroc
Useful for evaluation criteria comparison.
"Reading 19 clinical outcomes off 50 simulated futures, with no task-specific training, TWICE matched the best of 144 supervised configurations on held-out patients (mean AUROC 0.836 vs."
No benchmark or dataset names were extracted from the available abstract.
A digital twin of a patient in intensive care would forecast the patient's course and what a treatment would change.
Based on abstract + metadata only. Check the source paper before making high-confidence protocol decisions.
Human feedback protocol is explicit
No explicit human feedback protocol detected.
Evaluation mode is explicit
Detected: Automatic Metrics
Quality control reporting appears
No calibration/adjudication/IAA control explicitly detected.
Benchmark or dataset anchors are present
No benchmark/dataset anchor extracted from abstract.
Metric reporting is present
Detected: auroc