Skip to content
OpenTrain AIFor AI Companies

HFEPX · Eval paper review

Constructing and Validating Memorisation Audits for EHR Foundation Models

Inigo Stibbe, Joshua Placidi, Padmanabhan Ramnarayan, A. Aldo Faisal

Published

Nov 11, 2026

Citations

0

Trust level

Low

Usefulness score

25/100 (Low)

Extraction confidence

45% (Low)

Derived from extracted protocol signals and abstract evidence.

Rater population

Not reported

Signals refreshed

Nov 11, 2026

Should you rely on this paper?

This paper is adjacent to HFEPX scope and is best used for background context, not as a primary protocol reference.

Use this as background context only. Do not make protocol decisions from this page alone.

Best use

Background context only

Use if you need

A secondary eval reference to pair with stronger protocol papers.

What to verify

Validate the evaluation procedure and quality controls in the full paper before operational use.

Main weakness

The available metadata is too thin to trust this as a primary source.

Human feedback signal
Not explicit
Not explicit in abstract metadata
Evaluation signal
Detected
Eval setup described
Usefulness for eval research
25/100
Adjacent candidate

Treat as adjacent context, not a core eval-method reference.

Abstract

Autoregressive electronic health record (EHR) foundation models may disclose training information at inference, yet clinical predictability makes patient-specific memorisation difficult to distinguish from generalisation. We evaluate fixed-window token reconstruction, sensitive-attribute disclosure, and random patient-level canaries in GPT-2-style models trained on MIMIC-IV, across early, best-validation, and final checkpoints. Reconstruction improves with additional context, but training--held-out differences remain small. Trajectory-unique prompts containing limited clinical information produce no excess sensitive disclosure for training patients. In a matched model with random binary patient-level canaries, training-patient label-recovery AUROC increases from 0.512 to 0.549 while held-out recovery remains at chance. An overfit 1,000-patient positive control achieves near-perfect recovery, confirming sensitivity to strong memorisation. These results reveal weak cohort-level memorisation but no reliable patient-level disclosure under the evaluated attacks. They motivate clinically grounded inference-time audits that can detect patient-specific memorisation in existing models without retraining with canaries.

What we could verify

These are the protocol signals we could actually recover from the available paper metadata. Use them to decide whether this paper is worth deeper reading.

Human Feedback Types

missing

None explicit

No explicit feedback protocol extracted.

"Autoregressive electronic health record (EHR) foundation models may disclose training information at inference, yet clinical predictability makes patient-specific memorisation difficult to distinguish from generalisation."

Evaluation Modes

partial

Automatic Metrics

Includes extracted eval setup.

"Autoregressive electronic health record (EHR) foundation models may disclose training information at inference, yet clinical predictability makes patient-specific memorisation difficult to distinguish from generalisation."

Quality Controls

missing

Not reported

No explicit QC controls found.

"Autoregressive electronic health record (EHR) foundation models may disclose training information at inference, yet clinical predictability makes patient-specific memorisation difficult to distinguish from generalisation."

Benchmarks / Datasets

missing

Not extracted

No benchmark anchors detected.

"Autoregressive electronic health record (EHR) foundation models may disclose training information at inference, yet clinical predictability makes patient-specific memorisation difficult to distinguish from generalisation."

Reported Metrics

partial

Auroc

Useful for evaluation criteria comparison.

"In a matched model with random binary patient-level canaries, training-patient label-recovery AUROC increases from 0.512 to 0.549 while held-out recovery remains at chance."

Benchmarks and datasets

No benchmark or dataset names were extracted from the available abstract.

Reported metrics

auroc
Human feedback details
Uses human feedback
No
Feedback types
None
Rater population
Not reported
Unit of annotation
Trajectory (inferred)
Expertise required
Medicine
Evaluation details
Evaluation modes
Automatic Metrics
Agentic eval
Long Horizon
Quality controls
Not reported
Evidence quality
Low
Use this page as
Background context only

Research brief

Metadata summary

Autoregressive electronic health record (EHR) foundation models may disclose training information at inference, yet clinical predictability makes patient-specific memorisation difficult to distinguish from generalisation.

Based on abstract + metadata only. Check the source paper before making high-confidence protocol decisions.

Key takeaways

  • Autoregressive electronic health record (EHR) foundation models may disclose training information at inference, yet clinical predictability makes patient-specific memorisation difficult to distinguish from generalisation.
  • We evaluate fixed-window token reconstruction, sensitive-attribute disclosure, and random patient-level canaries in GPT-2-style models trained on MIMIC-IV, across early, best-validation, and final checkpoints.
  • Reconstruction improves with additional context, but training--held-out differences remain small.

Researcher actions

  • Compare this paper against nearby papers in the same arXiv category before using it for protocol decisions.
  • Check the full text for explicit evaluation design choices (raters, protocol, and metrics).
  • Use related-paper links to find stronger protocol-specific references.

Caveats

  • Generated from abstract + metadata only; no PDF parsing.
  • Signals below are heuristic and may miss details reported outside the abstract.

Recommended queries

Contribution summary

  • Autoregressive electronic health record (EHR) foundation models may disclose training information at inference, yet clinical predictability makes patient-specific memorisation difficult to distinguish from generalisation.
  • We evaluate fixed-window token reconstruction, sensitive-attribute disclosure, and random patient-level canaries in GPT-2-style models trained on MIMIC-IV, across early, best-validation, and final checkpoints.

Why it matters for eval

  • These results reveal weak cohort-level memorisation but no reliable patient-level disclosure under the evaluated attacks.

Researcher checklist

  • Human feedback protocol is explicit

    No explicit human feedback protocol detected.

  • Evaluation mode is explicit

    Detected: Automatic Metrics

  • Quality control reporting appears

    No calibration/adjudication/IAA control explicitly detected.

  • Benchmark or dataset anchors are present

    No benchmark/dataset anchor extracted from abstract.

  • Metric reporting is present

    Detected: auroc