Skip to content
OpenTrain AIFor AI Companies

HFEPX · Eval paper review

Surrogate-Assisted Compact-Model Extraction for SKY130 CMOS at 77 K

Aaron Wang, Olivia Gzamouranis, Vaibhav Lohia, Hershel Fei Xun Weiner +5 more

Published

Nov 16, 2026

Citations

0

Trust level

Low

Usefulness score

0/100 (Low)

Extraction confidence

30% (Low)

Derived from extracted protocol signals and abstract evidence.

Rater population

Not reported

Signals refreshed

Nov 16, 2026

Should you rely on this paper?

This paper is adjacent to HFEPX scope and is best used for background context, not as a primary protocol reference.

Use this as background context only. Do not make protocol decisions from this page alone.

Best use

Background context only

Use if you need

A secondary eval reference to pair with stronger protocol papers.

What to verify

Read the full paper before copying any benchmark, metric, or protocol choices.

Main weakness

This paper looks adjacent to evaluation work, but not like a strong protocol reference.

Human feedback signal
Not explicit
Not explicit in abstract metadata
Evaluation signal
Detected
Eval setup described
Usefulness for eval research
0/100
Adjacent candidate

Treat as adjacent context, not a core eval-method reference.

Abstract

Cryogenic circuit design requires compact transistor models that reproduce measured low-temperature behavior and run in standard circuit simulators. We fit BSIM4 parameters to measured I-V curves of SkyWater 130 nm (SKY130) transistors at 77 K using a neural surrogate of NGSpice. The surrogate maps compact-model parameters and device geometry to the complete set of output and transfer characteristics. Extraction is a bounded least-squares search: a bank of NGSpice simulations supplies initial candidates, finite differences of the surrogate supply the local Jacobian, and NGSpice re-simulates the resulting cards before selection. On 18 measured geometries, we compare a search over seven card parameters with a search over 43 parameters selected by NGSpice sensitivity. Relative to NGSpice re-simulations of the previously released cards, the two searches reduce the in-sample mean relative root-mean-square error (RRMS) by 17% and 26%, respectively. The 43-parameter search has the lower overall error, but the seven-parameter search has the lower mean on high-bias curves, and some individual curves have higher error than with the released cards under both searches.

What we could verify

These are the protocol signals we could actually recover from the available paper metadata. Use them to decide whether this paper is worth deeper reading.

Human Feedback Types

missing

None explicit

No explicit feedback protocol extracted.

"Cryogenic circuit design requires compact transistor models that reproduce measured low-temperature behavior and run in standard circuit simulators."

Evaluation Modes

partial

Simulation Env

Includes extracted eval setup.

"Cryogenic circuit design requires compact transistor models that reproduce measured low-temperature behavior and run in standard circuit simulators."

Quality Controls

missing

Not reported

No explicit QC controls found.

"Cryogenic circuit design requires compact transistor models that reproduce measured low-temperature behavior and run in standard circuit simulators."

Benchmarks / Datasets

missing

Not extracted

No benchmark anchors detected.

"Cryogenic circuit design requires compact transistor models that reproduce measured low-temperature behavior and run in standard circuit simulators."

Reported Metrics

missing

Not extracted

No metric anchors detected.

"Cryogenic circuit design requires compact transistor models that reproduce measured low-temperature behavior and run in standard circuit simulators."

Benchmarks and datasets

No benchmark or dataset names were extracted from the available abstract.

Reported metrics

No metric terms were extracted from the available abstract.

Human feedback details
Uses human feedback
No
Feedback types
None
Rater population
Not reported
Expertise required
General
Evaluation details
Evaluation modes
Simulation Env
Agentic eval
None
Quality controls
Not reported
Evidence quality
Low
Use this page as
Background context only

Research brief

Metadata summary

Cryogenic circuit design requires compact transistor models that reproduce measured low-temperature behavior and run in standard circuit simulators.

Based on abstract + metadata only. Check the source paper before making high-confidence protocol decisions.

Key takeaways

  • Cryogenic circuit design requires compact transistor models that reproduce measured low-temperature behavior and run in standard circuit simulators.
  • We fit BSIM4 parameters to measured I-V curves of SkyWater 130 nm (SKY130) transistors at 77 K using a neural surrogate of NGSpice.
  • The surrogate maps compact-model parameters and device geometry to the complete set of output and transfer characteristics.

Researcher actions

  • Compare this paper against nearby papers in the same arXiv category before using it for protocol decisions.
  • Check the full text for explicit evaluation design choices (raters, protocol, and metrics).
  • Use related-paper links to find stronger protocol-specific references.

Caveats

  • Generated from abstract + metadata only; no PDF parsing.
  • Signals below are heuristic and may miss details reported outside the abstract.

Recommended queries

Contribution summary

  • Cryogenic circuit design requires compact transistor models that reproduce measured low-temperature behavior and run in standard circuit simulators.
  • We fit BSIM4 parameters to measured I-V curves of SkyWater 130 nm (SKY130) transistors at 77 K using a neural surrogate of NGSpice.

Why it matters for eval

  • Abstract shows limited direct human-feedback or evaluation-protocol detail; use as adjacent methodological context.

Researcher checklist

  • Human feedback protocol is explicit

    No explicit human feedback protocol detected.

  • Evaluation mode is explicit

    Detected: Simulation Env

  • Quality control reporting appears

    No calibration/adjudication/IAA control explicitly detected.

  • Benchmark or dataset anchors are present

    No benchmark/dataset anchor extracted from abstract.

  • Metric reporting is present

    No metric terms extracted.