Human Feedback Types
missingNone explicit
No explicit feedback protocol extracted.
"Cryogenic circuit design requires compact transistor models that reproduce measured low-temperature behavior and run in standard circuit simulators."
HFEPX · Eval paper review
Aaron Wang, Olivia Gzamouranis, Vaibhav Lohia, Hershel Fei Xun Weiner +5 more
Published
Nov 16, 2026
Citations
0
Trust level
Low
Usefulness score
0/100 (Low)
Extraction confidence
30% (Low)
Derived from extracted protocol signals and abstract evidence.
Rater population
Not reported
Signals refreshed
Nov 16, 2026
This paper is adjacent to HFEPX scope and is best used for background context, not as a primary protocol reference.
Use this as background context only. Do not make protocol decisions from this page alone.
All signals on this page are inferred from the abstract only and may be inaccurate. Do not use this page as a primary protocol reference.
Best use
Background context only
Use if you need
A secondary eval reference to pair with stronger protocol papers.
What to verify
Read the full paper before copying any benchmark, metric, or protocol choices.
Main weakness
This paper looks adjacent to evaluation work, but not like a strong protocol reference.
Treat as adjacent context, not a core eval-method reference.
If you are doing eval pipeline work, start here
Cryogenic circuit design requires compact transistor models that reproduce measured low-temperature behavior and run in standard circuit simulators. We fit BSIM4 parameters to measured I-V curves of SkyWater 130 nm (SKY130) transistors at 77 K using a neural surrogate of NGSpice. The surrogate maps compact-model parameters and device geometry to the complete set of output and transfer characteristics. Extraction is a bounded least-squares search: a bank of NGSpice simulations supplies initial candidates, finite differences of the surrogate supply the local Jacobian, and NGSpice re-simulates the resulting cards before selection. On 18 measured geometries, we compare a search over seven card parameters with a search over 43 parameters selected by NGSpice sensitivity. Relative to NGSpice re-simulations of the previously released cards, the two searches reduce the in-sample mean relative root-mean-square error (RRMS) by 17% and 26%, respectively. The 43-parameter search has the lower overall error, but the seven-parameter search has the lower mean on high-bias curves, and some individual curves have higher error than with the released cards under both searches.
These are the protocol signals we could actually recover from the available paper metadata. Use them to decide whether this paper is worth deeper reading.
None explicit
No explicit feedback protocol extracted.
"Cryogenic circuit design requires compact transistor models that reproduce measured low-temperature behavior and run in standard circuit simulators."
Simulation Env
Includes extracted eval setup.
"Cryogenic circuit design requires compact transistor models that reproduce measured low-temperature behavior and run in standard circuit simulators."
Not reported
No explicit QC controls found.
"Cryogenic circuit design requires compact transistor models that reproduce measured low-temperature behavior and run in standard circuit simulators."
Not extracted
No benchmark anchors detected.
"Cryogenic circuit design requires compact transistor models that reproduce measured low-temperature behavior and run in standard circuit simulators."
Not extracted
No metric anchors detected.
"Cryogenic circuit design requires compact transistor models that reproduce measured low-temperature behavior and run in standard circuit simulators."
No benchmark or dataset names were extracted from the available abstract.
No metric terms were extracted from the available abstract.
Cryogenic circuit design requires compact transistor models that reproduce measured low-temperature behavior and run in standard circuit simulators.
Based on abstract + metadata only. Check the source paper before making high-confidence protocol decisions.
Human feedback protocol is explicit
No explicit human feedback protocol detected.
Evaluation mode is explicit
Detected: Simulation Env
Quality control reporting appears
No calibration/adjudication/IAA control explicitly detected.
Benchmark or dataset anchors are present
No benchmark/dataset anchor extracted from abstract.
Metric reporting is present
No metric terms extracted.