Skip to content
OpenTrain AIFor AI Companies

HFEPX · Eval paper review

Label leakage through file headers: geometry and batch confounds in public mammography datasets, and a pre-training acceptance gate

Achraf Toufah, Rana Saad, Moulay Youssef El Hafidi

Published

Nov 24, 2026

Citations

0

Trust level

Low

Usefulness score

0/100 (Low)

Extraction confidence

35% (Low)

Derived from extracted protocol signals and abstract evidence.

Rater population

Not reported

Signals refreshed

Nov 24, 2026

Should you rely on this paper?

This paper is adjacent to HFEPX scope and is best used for background context, not as a primary protocol reference.

Use this as background context only. Do not make protocol decisions from this page alone.

Best use

Background context only

Use if you need

A secondary eval reference to pair with stronger protocol papers.

What to verify

Validate the evaluation procedure and quality controls in the full paper before operational use.

Main weakness

This paper looks adjacent to evaluation work, but not like a strong protocol reference.

Human feedback signal
Not explicit
Not explicit in abstract metadata
Evaluation signal
Detected
Eval setup described
Usefulness for eval research
0/100
Adjacent candidate

Treat as adjacent context, not a core eval-method reference.

Abstract

A dataset whose diagnostic label can be recovered from non-diagnostic information yields high, reproducible and uninformative model performance. We applied pre-training controls that see only image geometry, global texture, a sub-collection identifier or one covariate to six public mammography datasets, against a stop threshold of AUC 0.60. In KAU-BCMD, geometry alone predicted the BI-RADS class at AUC 1.0000 in a local copy and at a mean of 0.979 in a public Kaggle archive; after resizing, texture alone gave 0.847. In CMMD, the sub-collection prefix predicted malignancy at 0.7753; the restricted sub-collection passed geometry (0.5000) and texture (0.5810) but failed an identifier-order control added post hoc (test AUC 0.9926). CBIS-DDSM exceeded the stop on geometry (pooled mean 0.654 over 20 splits), a verdict statistic chosen post hoc; its official mass and calcification splits did not. M-SYNTH, INbreast and a partial VinDr-Mammo copy passed the few controls run. We release the code and derived tables. There is no quantum component in the inference path.

What we could verify

These are the protocol signals we could actually recover from the available paper metadata. Use them to decide whether this paper is worth deeper reading.

Human Feedback Types

missing

None explicit

No explicit feedback protocol extracted.

"A dataset whose diagnostic label can be recovered from non-diagnostic information yields high, reproducible and uninformative model performance."

Evaluation Modes

partial

Automatic Metrics

Includes extracted eval setup.

"A dataset whose diagnostic label can be recovered from non-diagnostic information yields high, reproducible and uninformative model performance."

Quality Controls

missing

Not reported

No explicit QC controls found.

"A dataset whose diagnostic label can be recovered from non-diagnostic information yields high, reproducible and uninformative model performance."

Benchmarks / Datasets

missing

Not extracted

No benchmark anchors detected.

"A dataset whose diagnostic label can be recovered from non-diagnostic information yields high, reproducible and uninformative model performance."

Reported Metrics

partial

Auroc

Useful for evaluation criteria comparison.

"A dataset whose diagnostic label can be recovered from non-diagnostic information yields high, reproducible and uninformative model performance."

Benchmarks and datasets

No benchmark or dataset names were extracted from the available abstract.

Reported metrics

auroc
Human feedback details
Uses human feedback
No
Feedback types
None
Rater population
Not reported
Expertise required
Medicine, Coding
Evaluation details
Evaluation modes
Automatic Metrics
Agentic eval
None
Quality controls
Not reported
Evidence quality
Low
Use this page as
Background context only

Research brief

Metadata summary

A dataset whose diagnostic label can be recovered from non-diagnostic information yields high, reproducible and uninformative model performance.

Based on abstract + metadata only. Check the source paper before making high-confidence protocol decisions.

Key takeaways

  • A dataset whose diagnostic label can be recovered from non-diagnostic information yields high, reproducible and uninformative model performance.
  • We applied pre-training controls that see only image geometry, global texture, a sub-collection identifier or one covariate to six public mammography datasets, against a stop threshold of AUC 0.60.
  • In KAU-BCMD, geometry alone predicted the BI-RADS class at AUC 1.0000 in a local copy and at a mean of 0.979 in a public Kaggle archive; after resizing, texture alone gave 0.847.

Researcher actions

  • Compare this paper against nearby papers in the same arXiv category before using it for protocol decisions.
  • Check the full text for explicit evaluation design choices (raters, protocol, and metrics).
  • Use related-paper links to find stronger protocol-specific references.

Caveats

  • Generated from abstract + metadata only; no PDF parsing.
  • Signals below are heuristic and may miss details reported outside the abstract.

Recommended queries

Contribution summary

  • A dataset whose diagnostic label can be recovered from non-diagnostic information yields high, reproducible and uninformative model performance.
  • We applied pre-training controls that see only image geometry, global texture, a sub-collection identifier or one covariate to six public mammography datasets, against a stop threshold of AUC 0.60.

Why it matters for eval

  • Abstract shows limited direct human-feedback or evaluation-protocol detail; use as adjacent methodological context.

Researcher checklist

  • Human feedback protocol is explicit

    No explicit human feedback protocol detected.

  • Evaluation mode is explicit

    Detected: Automatic Metrics

  • Quality control reporting appears

    No calibration/adjudication/IAA control explicitly detected.

  • Benchmark or dataset anchors are present

    No benchmark/dataset anchor extracted from abstract.

  • Metric reporting is present

    Detected: auroc