Skip to content
OpenTrain AIFor AI Companies

TIBECG: Temporal Information Bottleneck for Lead-Specific Demographic Privacy in ECG Waveform Release

Tsai-Min Chen, Jun SeitaPublished Nov 16, 2026
arXiv PDF
Researcher verdict
Context only
Use as context only
Benchmark evidence
Missing
Not verified yet
Time to first repro
A few days
Plan setup time
Risk flags
2
Review before use

No concrete benchmark grounding is available yet. Treat the page as context or an implementation starting point only.

Abstract

Domain fit: Niche / domain-specific · No strong AI-core implementation/artifact signals were detected from current providers.

Transmitting an electrocardiogram (ECG) waveform can expose demographic information beyond an intended diagnostic task. We evaluate TIBECG, an architectural temporal information bottleneck, on individual leads extracted from hospital twelve-lead recordings. A 2,302,337-parameter processor varies its latent length while retaining the same nine-score consistency objective, without age or sex labels in protector fitting. Across 6,386 recordings, ten folds, 12 leads and 21 lengths, retrospective selections retained at least 95% of each lead's clean macro-F1. Their weaker age/sex interval gain exceeded the best eligible conventional transformation on all leads, by a median 22.08 percentage points. The implemented sampling-rate comparison shows that direct downsampling usually suppresses demographic inference more strongly but at a larger loss of diagnostic utility, whereas TIBECG favors utility preservation. Selection stability also varies by lead. Lower latent Kullback-Leibler (KL) divergence does not reliably rank residual sex leakage at a fixed length. These findings support lead-specific evaluation of waveform processing, not validated consumer deployment or expert-readable reconstruction. When the waveform-input diagnostic classifier is hosted as part of a proprietary cloud service rather than deployed on the device, waveform transmission is required to obtain its scores.

Results and benchmarks

Transmitting an electrocardiogram (ECG) waveform can expose demographic information beyond an intended diagnostic task.

Implementation

No direct implementation yet

Maintained implementation evidence is not confirmed for this paper yet.

Use the implementation status and reproduction sections for the current action plan.

Implementation evidence summary
Confidence: low

Recommendation evidence is currently too limited for a maintained-repo choice. Use Implementation Status and Reproduction Path for a practical baseline plan.

Reproduction risks
  • Estimate is based on paper-only reproduction flow

Reproduction readiness

Time to first repro: days
Last checked: Nov 25, 2026

No repo

No verified implementation available

  • No maintained repository has been identified for this paper. Check adjacent implementations or HF artifacts below.

Hardware requirements

  • Expect multi-day setup/compute for meaningful reproduction based on current guidance.

Hugging Face artifacts

No trustworthy direct or curated related Hugging Face artifacts were found yet. Use targeted searches to quickly locate candidate models, datasets, and demos.

Tip: start with models, then check datasets and spaces if you need evaluation data or demos.

Research context

Evaluation and human feedback data

Open this paper in HFEPX to review benchmark signals, evaluation modes, and human-feedback protocol context.

Open in HFEPX