Stop Early, Stay Simple: Evidence Acquisition for Power System Fault and Attack Diagnosis
Abstract
Domain fit: Niche / domain-specific · No strong AI-core implementation/artifact signals were detected from current providers.
Diagnostic models for cyber-physical power systems usually inspect every telemetry source for every event, although some events are clear from one source and others need several. We ask when a learned policy for choosing that evidence is worth its added complexity. To answer this, we present ActiGrid, a benchmark framework for active evidence acquisition that pairs a classifier trained to tolerate missing modalities with a Double Deep Q-Network (DQN), which either requests another source or stops and diagnoses but never operates grid actuators. On the public TU Delft digital substation and MSU/ORNL power system attack benchmarks, we compare the DQN with fixed subsets and orders, calibrated entropy stopping, a greedy value of information rule, and tree ensembles trained per subset. The learned policy does adapt to what it observes, yet it is statistically indistinguishable from entropy stopping on TU Delft and Pareto dominated by simple controls on MSU/ORNL, while compact subset classifiers outperform it while reading fewer sources on both benchmarks. Entropy stopping run over those subset classifiers reaches the highest mean Macro-F1 on TU Delft (0.928 while reading 57% of the sources) but brings no saving over a static three source subset on MSU/ORNL, where no method exceeds 0.45 Macro-F1. Selective acquisition can pay off, but on these benchmarks it does not need a learned policy.
Results and benchmarks
Diagnostic models for cyber-physical power systems usually inspect every telemetry source for every event, although some events are clear from one source and others need several.
| Task | Dataset | Metric | Value | Source |
|---|---|---|---|---|
| Evidence Acquisition Power System Fault Attack | Order+entropy | Macro-F1 | 0.732 | paper-derived |
| Evidence Acquisition Power System Fault Attack | HGB, k = 1 k=1 | Macro-F1 | 0.333 | paper-derived |
Audit each benchmark finding before selecting an implementation path.
Implementation
No direct implementation yet
Maintained implementation evidence is not confirmed for this paper yet.
Use the implementation status and reproduction sections for the current action plan.
No verified maintained repo yet
There is no verified maintained implementation yet. Use this baseline plan to decide whether to prototype now or defer.
- No direct maintained implementation was found. Use the paper PDF and citation graph to design a baseline reproduction.
- Track assumptions and missing details in an experiment log before coding.
Time to first repro: a few days
Recommendation evidence is currently too limited for a maintained-repo choice. Use Implementation Status and Reproduction Path for a practical baseline plan.
- Estimate is based on paper-only reproduction flow
Reproduction readiness
No repo
No verified implementation available
- No maintained repository has been identified for this paper. Check adjacent implementations or HF artifacts below.
Hardware requirements
- Expect multi-day setup/compute for meaningful reproduction based on current guidance.
Hugging Face artifacts
No trustworthy direct or curated related Hugging Face artifacts were found yet. Use targeted searches to quickly locate candidate models, datasets, and demos.
Tip: start with models, then check datasets and spaces if you need evaluation data or demos.
Research context
Tasks
Evidence Acquisition Power System Fault Attack
Methods
None detected
Domains
None detected
Open this paper in HFEPX to review benchmark signals, evaluation modes, and human-feedback protocol context.
Open in HFEPXJump to Paper2Code search queries derived from this paper's research context.