Skip to content
OpenTrain AIFor AI Companies

Stop Early, Stay Simple: Evidence Acquisition for Power System Fault and Attack Diagnosis

S M Zia Ur Rashid, Sazidul Islam Hira, Rupesh Sah, Suman RathPublished Nov 16, 2026
arXiv PDF
Researcher verdict
Context only
Use as context only
Benchmark evidence
Thin evidence
Verify before relying
Time to first repro
A few days
Plan setup time
Risk flags
2
Review before use

Abstract

Domain fit: Niche / domain-specific · No strong AI-core implementation/artifact signals were detected from current providers.

Diagnostic models for cyber-physical power systems usually inspect every telemetry source for every event, although some events are clear from one source and others need several. We ask when a learned policy for choosing that evidence is worth its added complexity. To answer this, we present ActiGrid, a benchmark framework for active evidence acquisition that pairs a classifier trained to tolerate missing modalities with a Double Deep Q-Network (DQN), which either requests another source or stops and diagnoses but never operates grid actuators. On the public TU Delft digital substation and MSU/ORNL power system attack benchmarks, we compare the DQN with fixed subsets and orders, calibrated entropy stopping, a greedy value of information rule, and tree ensembles trained per subset. The learned policy does adapt to what it observes, yet it is statistically indistinguishable from entropy stopping on TU Delft and Pareto dominated by simple controls on MSU/ORNL, while compact subset classifiers outperform it while reading fewer sources on both benchmarks. Entropy stopping run over those subset classifiers reaches the highest mean Macro-F1 on TU Delft (0.928 while reading 57% of the sources) but brings no saving over a static three source subset on MSU/ORNL, where no method exceeds 0.45 Macro-F1. Selective acquisition can pay off, but on these benchmarks it does not need a learned policy.

Results and benchmarks

Diagnostic models for cyber-physical power systems usually inspect every telemetry source for every event, although some events are clear from one source and others need several.
Task Dataset Metric Value Source
Evidence Acquisition Power System Fault Attack Order+entropy Macro-F1 0.732 paper-derived
Evidence Acquisition Power System Fault Attack HGB, k = 1 k=1 Macro-F1 0.333 paper-derived

Audit each benchmark finding before selecting an implementation path.

Implementation

No direct implementation yet

Maintained implementation evidence is not confirmed for this paper yet.

Use the implementation status and reproduction sections for the current action plan.

Implementation evidence summary
Confidence: low

Recommendation evidence is currently too limited for a maintained-repo choice. Use Implementation Status and Reproduction Path for a practical baseline plan.

Reproduction risks
  • Estimate is based on paper-only reproduction flow

Reproduction readiness

Time to first repro: days
Last checked: Nov 24, 2026

No repo

No verified implementation available

  • No maintained repository has been identified for this paper. Check adjacent implementations or HF artifacts below.

Hardware requirements

  • Expect multi-day setup/compute for meaningful reproduction based on current guidance.

Hugging Face artifacts

No trustworthy direct or curated related Hugging Face artifacts were found yet. Use targeted searches to quickly locate candidate models, datasets, and demos.

Tip: start with models, then check datasets and spaces if you need evaluation data or demos.

Research context

Tasks

Evidence Acquisition Power System Fault Attack

Methods

None detected

Domains

None detected

Evaluation and human feedback data

Open this paper in HFEPX to review benchmark signals, evaluation modes, and human-feedback protocol context.

Open in HFEPX
Explore similar papers

Jump to Paper2Code search queries derived from this paper's research context.