Skip to content
OpenTrain AIFor AI Companies

RibAssist 3D: Biplanar Rib-Fracture Detection, Addressing, and Selective 3D Localization from CT-Derived Projections

Kabila Haile SobokaPublished Aug 7, 2026
arXiv PDF
Researcher verdict
Context only
Use as context only
Benchmark evidence
Missing
Not verified yet
Time to first repro
A few days
Plan setup time
Risk flags
2
Review before use

Abstract

Domain fit: Niche / domain-specific · No strong AI-core implementation/artifact signals were detected from current providers.

Rib fractures are common and time-consuming to localize on computed tomography (CT). We ask whether fractures detected independently in two orthogonal CT-derived projections (anteroposterior and lateral) can be paired across views and triangulated into reliable 3D points at a controlled rate of false outputs, and we answer it with a staged diagnostic study. The projection geometry is exact, and given correct correspondence, localization is accurate (median 4.0 mm, 88% within 10 mm, 93.6% rib-exact). On a sealed 55-case cohort, a large share of fractures is in principle recoverable (61.1% dual-view availability, and a correct pair present in the candidate graph for 58.4% of fractures), yet the binding limitation is neither geometry nor localization but confidence-limited cross-view correspondence. A controlled detector-by-correspondence factorial attributes the operational gain to lateral-detector quality rather than the tested matching methods; retraining the lateral detector produces the first nonzero controlled-budget reconstructions. Under a deliberately conservative commitment policy, a pre-specified sealed pass promotes 15 of 601 fractures to correct 3D localizations at 0.436 false points per case (2.50% end-to-end commitment yield), and committed points are accurate (median 1.49 mm, 93% rib-exact). The low yield is a consequence of confidence-gated abstention, not of geometry or detection: the study establishes a reproducible framework for selective 3D localization and identifies cross-view correspondence as the dominant operational bottleneck.

Results and benchmarks

Freshness tier: warm
Rib fractures are common and time-consuming to localize on computed tomography (CT).

Implementation

No direct implementation yet

Maintained implementation evidence is not confirmed for this paper yet.

Use the implementation status and reproduction sections for the current action plan.

Implementation evidence summary
Confidence: low

Recommendation evidence is currently too limited for a maintained-repo choice. Use Implementation Status and Reproduction Path for a practical baseline plan.

Reproduction risks
  • Estimate is based on paper-only reproduction flow

Reproduction readiness

Time to first repro: days
Last checked: Oct 31, 2026

No repo

No verified implementation available

  • No maintained repository has been identified for this paper. Check adjacent implementations or HF artifacts below.

Hardware requirements

  • Expect multi-day setup/compute for meaningful reproduction based on current guidance.

Repositories and ecosystem

No additional verified repositories beyond the primary recommendation.

Hugging Face artifacts

No trustworthy direct or curated related Hugging Face artifacts were found yet. Use targeted searches to quickly locate candidate models, datasets, and demos.

Tip: start with models, then check datasets and spaces if you need evaluation data or demos.

Research context

Evaluation and human feedback data

Open this paper in HFEPX to review benchmark signals, evaluation modes, and human-feedback protocol context.

Open in HFEPX