Skip to content
OpenTrain AIFor AI Companies

RespCCT and FreqCCT: Compact, Explainable and Cost-Aware Convolutional Transformers for Multi-Class Respiratory Disease Classification

Auntor Chakma, Mst. Farhana Akter, Abu Henaf Rashid Ahmad Mufti, Asmana YasminPublished Nov 18, 2026
arXiv PDF
Researcher verdict
Context only
Use as context only
Benchmark evidence
Thin evidence
Verify before relying
Time to first repro
A few days
Plan setup time
Risk flags
2
Review before use

Some benchmark signal exists in the extracted evidence, but it is not structured strongly enough yet for a confident benchmark decision.

Abstract

Domain fit: AI-adjacent · Paper appears method- or tooling-adjacent to AI workflows with partial ecosystem coverage.

Chest auscultation depends on the listener, and software that classifies lung sounds could give a second reading where trained listeners are scarce. The most accurate published classifiers fine-tune large pretrained networks, and their accuracy is rarely reported with running cost or paired statistics. This study makes three contributions. (i) It proposes RespCCT and FreqCCT, two compact convolutional transformers of 173,187 and 124,999 parameters that learn from random initialization on mel, constant-Q and cepstral images of 5 s frames from three public databases, ICBHI, KAUH and RD@TR, with 1,665 audio files in seven classes. (ii) It compares both models with five ImageNet-pretrained networks and larger distilled variants on one test set, using paired bootstrap intervals. (iii) It measures the cost of every pipeline stage on one CPU thread, tests whether attribution maps depend on the trained weights, and probes whether the learned features reveal the recording source. On the test fold, RespCCT reaches an accuracy of 98.13% and a macro F1 of 0.970, and FreqCCT reaches 97.58% and 0.951. Over five folds, RespCCT with three seeds reaches 97.65% and 0.959, and FreqCCT with one seed reaches 96.95% and 0.941. The two strongest pretrained networks reach a macro F1 of 0.984, whereas RespCCT needs 2.0 to 64.6 times less weight storage. Computing the three input images takes longer than running either model, and a linear probe identifies the source database with 0.958 accuracy. A team can weigh accuracy against storage and time before device testing.

Results and benchmarks

Chest auscultation depends on the listener, and software that classifies lung sounds could give a second reading where trained listeners are scarce.

Implementation

No direct implementation yet

Maintained implementation evidence is not confirmed for this paper yet.

Use the implementation status and reproduction sections for the current action plan.

Implementation evidence summary
Confidence: low

Recommendation evidence is currently too limited for a maintained-repo choice. Use Implementation Status and Reproduction Path for a practical baseline plan.

Reproduction risks
  • Estimate is based on paper-only reproduction flow

Reproduction readiness

Time to first repro: days
Last checked: Nov 25, 2026

No repo

No verified implementation available

  • No maintained repository has been identified for this paper. Check adjacent implementations or HF artifacts below.

Hardware requirements

  • Expect multi-day setup/compute for meaningful reproduction based on current guidance.

Framework baselines

Hugging Face artifacts

No trustworthy direct or curated related Hugging Face artifacts were found yet. Use targeted searches to quickly locate candidate models, datasets, and demos.

Tip: start with models, then check datasets and spaces if you need evaluation data or demos.

Research context

Tasks

Image classification

Methods

Transformer

Domains

Computer vision

Evaluation and human feedback data

Open this paper in HFEPX to review benchmark signals, evaluation modes, and human-feedback protocol context.

Open in HFEPX
Explore similar papers

Jump to Paper2Code search queries derived from this paper's research context.