Online Identification Can Replace a Floor-Plan Prior on Unseen Buildings
No concrete benchmark grounding is available yet. Treat the page as context or an implementation starting point only.
Abstract
Domain fit: Niche / domain-specific · No strong AI-core implementation/artifact signals were detected from current providers.
The Smart Buildings Challenge asks for one HVAC control policy that runs office buildings and weather it has never seen, from the building's metadata and sensor streams alone. Our controller sees no data from the target building before it runs and is not tuned per building; its few global constants were set on development scenarios. Each zone has a first-order grey-box model that starts from coefficients computed from the floor plan and is updated online by recursive least squares, and a planner and a closed-form mapping turn the models into plant commands. On two sets of buildings and weather that we generated, a validation set and a stress set with real-year weather, it scores 0.145 and 0.159 times the starter kit's PID baseline, and 0.095 times on a holdout built after all versions were fixed and scored once. It improves on every building, also against our two implementations of ASHRAE Guideline 36: per set it scores 0.60 to 0.71 times a basic version and 0.83 to 0.96 times one partly tuned on the public leaderboard, which wins one of 54 scenarios; with a 5 °C frost target for empty zones on both, the margin over the tuned version shrinks to 1.4% on the stress set, where one of six buildings is 0.2% worse. In an ablation on a reduced-order model, removing both the floor-plan prior and online identification costs 28%, 20% and 42% on the validation, stress and holdout sets, far more than the two effects combined: either source of building-specific information recovers most of what is lost without both. On one office floor in a second simulator, BOPTEST, this does not carry over: with identification on, the two priors give similar results, but the floor-plan prior alone, with constants fitted on the competition's simulator, is the least stable arm. These simulation results motivate testing floor-plan-initialised adaptive control in buildings that have drawings but no operating data.
Results and benchmarks
The Smart Buildings Challenge asks for one HVAC control policy that runs office buildings and weather it has never seen, from the building's metadata and sensor streams alone.
Implementation
No direct implementation yet
Maintained implementation evidence is not confirmed for this paper yet.
Use the implementation status and reproduction sections for the current action plan.
No verified maintained repo yet
There is no verified maintained implementation yet. Use this baseline plan to decide whether to prototype now or defer.
- No direct maintained implementation was found. Use the paper PDF and citation graph to design a baseline reproduction.
- Track assumptions and missing details in an experiment log before coding.
Time to first repro: a few days
Recommendation evidence is currently too limited for a maintained-repo choice. Use Implementation Status and Reproduction Path for a practical baseline plan.
- Estimate is based on paper-only reproduction flow
Reproduction readiness
No repo
No verified implementation available
- No maintained repository has been identified for this paper. Check adjacent implementations or HF artifacts below.
Hardware requirements
- Expect multi-day setup/compute for meaningful reproduction based on current guidance.
Validation caveat
Hugging Face artifacts
No trustworthy direct or curated related Hugging Face artifacts were found yet. Use targeted searches to quickly locate candidate models, datasets, and demos.
Models
Datasets
Spaces
Tip: start with models, then check datasets and spaces if you need evaluation data or demos.
Research context
Tasks
Scientific computing
Methods
None detected
Domains
None detected
Open this paper in HFEPX to review benchmark signals, evaluation modes, and human-feedback protocol context.
Open in HFEPXJump to Paper2Code search queries derived from this paper's research context.