Skip to content
OpenTrain AIFor AI Companies

Lightweight Low-Frequency Non-Intrusive Load Monitoring via Karhunen-Loève Feature Distillation and Temporal Convolutional Networks

Sanka Peeris, Pandula Thennakoon, Praveen Sumanasekara, Roshan Godaliyadda, Parakrama Ekanayake +1 morePublished Nov 19, 2026
arXiv PDF
Researcher verdict
Context only
Use as context only
Benchmark evidence
Missing
Not verified yet
Time to first repro
A few hours
Fast first run
Risk flags
1
Review before use

No concrete benchmark grounding is available yet. Treat the page as context or an implementation starting point only.

Abstract

Domain fit: Niche / domain-specific · No strong AI-core implementation/artifact signals were detected from current providers.

Non-Intrusive Load Monitoring (NILM) is a critical enabler for demand-side management which allows for smart grid optimization. A deployment-ready NILM solution necessitates three key features: accurate disaggregation, low-frequency sampling, and low computational cost. This paper proposes a lightweight, edge-oriented NILM framework that combines activity-boundary-aware synthetic data augmentation with Karhunen-Loève Transform (KLT) feature extraction and a Temporal Convolutional Network (TCN). The augmentation stage extracts and recombines complete or near-complete appliance activation segments so that the model can be trained without new fully labeled household aggregates. The KLT filter bank extracts decorrelated, appliance-informed temporal features which are then fed into a compact TCN along with the original aggregate for energy disaggregation. Evaluations on two standard NILM datasets, UK-DALE and REDD, at 10-s sampling and with leave-one-house-out testing, demonstrate that the proposed architecture achieves comparable or superior disaggregation accuracy relative to NILMFormer, BERT4NILM, BiLSTM, and BiGRU. The computational footprint of the framework is 31,009 parameters, the fewest of the five models compared, and on a single CPU thread it needs 2.78 ms per 1000 samples, 84-95% less than the baselines. These results demonstrate a favorable accuracy-efficiency tradeoff for low-frequency smart-meter NILM.

Results and benchmarks

Non-Intrusive Load Monitoring (NILM) is a critical enabler for demand-side management which allows for smart grid optimization.

Implementation

No direct implementation yet

Maintained implementation evidence is not confirmed for this paper yet.

Use the implementation status and reproduction sections for the current action plan.

Implementation evidence summary
Confidence: low

This is primarily a method paper. Reproduce it within a maintained framework baseline instead of chasing paper-specific repos.

Reproduction risks
  • No maintained paper-verified implementation is currently available

Reproduction readiness

Time to first repro: hours
Last checked: Nov 25, 2026

No repo

No verified implementation available

  • No maintained repository has been identified for this paper. Check adjacent implementations or HF artifacts below.

Hugging Face artifacts

No trustworthy direct or curated related Hugging Face artifacts were found yet. Use targeted searches to quickly locate candidate models, datasets, and demos.

Tip: start with models, then check datasets and spaces if you need evaluation data or demos.

Research context

Evaluation and human feedback data

Open this paper in HFEPX to review benchmark signals, evaluation modes, and human-feedback protocol context.

Open in HFEPX