Lesion-Aware Explainable AI for Diabetic Retinopathy Grading from Fundus Images
No concrete benchmark grounding is available yet. Treat the page as context or an implementation starting point only.
Abstract
Domain fit: AI-adjacent · Paper appears method- or tooling-adjacent to AI workflows with partial ecosystem coverage.
Post-hoc explanations of deep-learning models for diabetic retinopathy (DR) grading are difficult to trust because different attribution methods highlight different retinal regions for the same image, and a visually plausible heatmap does not show that the highlighted pixels drive the prediction. We propose the Consensus-Calibrated Explanation Map (CCEM), which fuses Grad-CAM++, Ada-SISE, and SmoothGrad Integrated Gradients (SG-IG) using image-specific weights derived from annotation-free reliability cues: deletion sensitivity, inter-method agreement, compactness, retinal containment, and peak structure. CCEM explains a frozen ordinal grader, an EfficientNet-B7 with CBAM and a scalar regression head, pre-trained on EyePACS 2015 in Stage 1 and fine-tuned on APTOS 2019 in Stage 2 with quadratic weighted kappa (QWK)-optimized thresholds; it reaches a QWK of 0.920 on the hidden Kaggle test set and 0.559 on the external MAPLES-DR cohort. Explanations are evaluated on MAPLES-DR, 198 MESSIDOR images with expert pixel-level lesion annotations that are never used for training, threshold fitting, or fusion. On the 193 images with annotated lesions, CCEM obtains the highest Soft Pointing Game score (69.61%; 95% CI 63.7-75.3), defined as the ratio of the strongest lesion-supported saliency to the global map maximum rather than a lesion detection rate, together with the lowest deletion AUC (0.570) and the best deletion-insertion balance (0.115); each gain is significant against the strongest single explainer on paired tests. Annotation-free, per-image reliability weighting therefore turns three disagreeing explainers into one map whose peak evidence is more lesion-supported and more faithful to the model than that of any single explainer.
Results and benchmarks
Post-hoc explanations of deep-learning models for diabetic retinopathy (DR) grading are difficult to trust because different attribution methods highlight different retinal regions for the same image, and a visually plausible heatmap does not show that the highlighted pixels drive the prediction.
Implementation
No direct implementation yet
Maintained implementation evidence is not confirmed for this paper yet.
Use the implementation status and reproduction sections for the current action plan.
No verified maintained repo yet
There is no verified maintained implementation yet. Use this baseline plan to decide whether to prototype now or defer.
- No direct maintained implementation was found. Use the paper PDF and citation graph to design a baseline reproduction.
- Track assumptions and missing details in an experiment log before coding.
Time to first repro: a few days
Recommendation evidence is currently too limited for a maintained-repo choice. Use Implementation Status and Reproduction Path for a practical baseline plan.
- Estimate is based on paper-only reproduction flow
Reproduction readiness
No repo
No verified implementation available
- No maintained repository has been identified for this paper. Check adjacent implementations or HF artifacts below.
Hardware requirements
- Expect multi-day setup/compute for meaningful reproduction based on current guidance.
Validation caveat
Hugging Face artifacts
No trustworthy direct or curated related Hugging Face artifacts were found yet. Use targeted searches to quickly locate candidate models, datasets, and demos.
Datasets
Tip: start with models, then check datasets and spaces if you need evaluation data or demos.
Research context
Tasks
None detected
Methods
None detected
Domains
Computer vision
Open this paper in HFEPX to review benchmark signals, evaluation modes, and human-feedback protocol context.
Open in HFEPXJump to Paper2Code search queries derived from this paper's research context.