Large Reported CHB-MIT Adaptation Gains Disappear with Pretrained Encoders and Matched Probes
Abstract
Domain fit: Niche / domain-specific · No strong AI-core implementation/artifact signals were detected from current providers.
Dani and Liebe (2026) (DL) report that adapting the final encoder block of BIOT and CBraMod with self-supervised learning (SSL) improves CHB-MIT seizure-detection ROC-AUC by 36.2 and 29.5 points over linear probing. We investigate these results with their released code and an independent pipeline. The release loads pretrained weights for adaptation only when an otherwise unset configuration key is supplied, and its CBraMod probe reads the reconstruction head with dropout active. With pretrained initialisation and a probe on the encoder output in evaluation mode, the fixed-recipe adaptation gain on DL's split is -0.6 points for BIOT (95% interval [-3.8, +2.6]) and +0.01 for CBraMod ([-0.02, +0.04]) across five seeds. Across DL's split and five subject rotations on CHB-MIT and Siena Scalp EEG, with equally tuned linear probes (30 configurations, up to 500 epochs, validation-based early stopping), mean adaptation effects range from -1.1 to +5.7 ROC-AUC points over 18 comparisons (related settings and feature variants). Twelve of 18 support equivalence within +/-3 points under dependence-adjusted inference (8 of 12 rotation and 4 of 6 fixed-split comparisons); six are unresolved. After correcting rotation intervals for dependence, no positive effect has a 95% interval excluding zero. The +/-3 margin is an analysis threshold, not a clinically validated one, and smaller margins support fewer equivalences. Two fixed-probe gains near +21 points shrink under the same tuning, with smaller benefits unresolved. We also audit a CHB-MIT protocol shared by at least 14 papers. No tested configuration reproduces DL Table 1 as a whole. These findings concern the tested configurations; the encoder-level probe and subsequent checks were chosen post hoc.
Results and benchmarks
Dani and Liebe (2026) (DL) report that adapting the final encoder block of BIOT and CBraMod with self-supervised learning (SSL) improves CHB-MIT seizure-detection ROC-AUC by 36.2 and 29.5 points over linear probing.
Benchmark evidence is limited
Evidence graph: 2 refs, 1 links.
Utility signals: depth 60/100, grounding 58/100, status medium.
Implementation
No direct implementation yet
Maintained implementation evidence is not confirmed for this paper yet.
Use the implementation status and reproduction sections for the current action plan.
No verified maintained repo yet
There is no verified maintained implementation yet. Use this baseline plan to decide whether to prototype now or defer.
- No direct maintained implementation was found. Use the paper PDF and citation graph to design a baseline reproduction.
- Track assumptions and missing details in an experiment log before coding.
Time to first repro: a few days
Recommendation evidence is currently too limited for a maintained-repo choice. Use Implementation Status and Reproduction Path for a practical baseline plan.
- Estimate is based on paper-only reproduction flow
Reproduction readiness
No repo
No verified implementation available
- No maintained repository has been identified for this paper. Check adjacent implementations or HF artifacts below.
Hardware requirements
- Expect multi-day setup/compute for meaningful reproduction based on current guidance.
Validation caveat
Hugging Face artifacts
No trustworthy direct or curated related Hugging Face artifacts were found yet. Use targeted searches to quickly locate candidate models, datasets, and demos.
Models
Datasets
Spaces
Tip: start with models, then check datasets and spaces if you need evaluation data or demos.
Research context
Open this paper in HFEPX to review benchmark signals, evaluation modes, and human-feedback protocol context.
Open in HFEPX