Skip to content
OpenTrain AIFor AI Companies

How Well Do Generalist CT Foundation Models Differentiate Liver Tumors?

Yosuke Yamagishi, Tomohiro Kikuchi, Shouhei Hanaoka, Takeharu Yoshikawa, Osamu AbePublished Nov 18, 2026
arXiv PDF
Researcher verdict
Context only
Use as context only
Benchmark evidence
Thin evidence
Verify before relying
Time to first repro
A few days
Plan setup time
Risk flags
2
Review before use

Some benchmark signal exists in the extracted evidence, but it is not structured strongly enough yet for a confident benchmark decision.

Abstract

Domain fit: AI-adjacent · Paper appears method- or tooling-adjacent to AI workflows with partial ecosystem coverage.

Generalist CT foundation models detect many findings with high performance, but their ability to differentiate detected lesions remains largely unevaluated. This retrospective study evaluated two generalist models, RADAR and Merlin, for differentiating liver tumors using a public single-institution multiphase CT dataset (517 cases: hepatocellular carcinoma, intrahepatic cholangiocarcinoma, breast and colorectal cancer liver metastases, and hemangioma). The models were evaluated in a zero-shot setting using their existing outputs and with linear probing, in which only a linear classifier was trained on frozen image features (stratified fivefold cross-validation repeated five times). In the zero-shot setting, RADAR achieved an accuracy of 54.4% (95% CI: 49.9, 58.8) and a $κ$ of 0.37 for four-class differentiation at the portal venous phase and predicted 31% (129 of 421) of malignant tumors as hemangioma. With linear probing of four-phase features, its accuracy improved to 79.9% (95% CI: 76.6, 83.4) with a $κ$ of 0.72, and 1% (five of 421) of malignant tumors were predicted as hemangioma; Merlin achieved an accuracy of 60.9% (95% CI: 56.9, 65.0). Generalist CT foundation models showed limited zero-shot ability to differentiate liver tumors, which improved substantially with linear probing alone.

Results and benchmarks

Generalist CT foundation models detect many findings with high performance, but their ability to differentiate detected lesions remains largely unevaluated.

Implementation

No direct implementation yet

Maintained implementation evidence is not confirmed for this paper yet.

Use the implementation status and reproduction sections for the current action plan.

Implementation evidence summary
Confidence: low

Recommendation evidence is currently too limited for a maintained-repo choice. Use Implementation Status and Reproduction Path for a practical baseline plan.

Reproduction risks
  • Estimate is based on paper-only reproduction flow

Reproduction readiness

Time to first repro: days
Last checked: Nov 25, 2026

No repo

No verified implementation available

  • No maintained repository has been identified for this paper. Check adjacent implementations or HF artifacts below.

Hardware requirements

  • Expect multi-day setup/compute for meaningful reproduction based on current guidance.

Hugging Face artifacts

No trustworthy direct or curated related Hugging Face artifacts were found yet. Use targeted searches to quickly locate candidate models, datasets, and demos.

Tip: start with models, then check datasets and spaces if you need evaluation data or demos.

Research context

Tasks

Computer vision

Methods

None detected

Domains

Computer vision

Evaluation and human feedback data

Open this paper in HFEPX to review benchmark signals, evaluation modes, and human-feedback protocol context.

Open in HFEPX
Explore similar papers

Jump to Paper2Code search queries derived from this paper's research context.