Geometry-bridge flow matching for blind rigid-motion correction in head cone-beam CT

Sungho Yun, Seungryong ChoPublished Nov 18, 2026
arXiv PDF
Researcher verdict
Context only
Use as context only
Benchmark evidence
Missing
Not verified yet
Time to first repro
A few days
Plan setup time
Risk flags
2
Review before use

No concrete benchmark grounding is available yet. Treat the page as context or an implementation starting point only.

Abstract

Domain fit: AI-adjacent · Paper appears method- or tooling-adjacent to AI workflows with partial ecosystem coverage.

Rigid motion of a patient head during head cone-beam CT (CBCT) scan can degrade image quality and complicate recovery of accurate anatomical structures from the measured projections. We present a 3D flow-matching prior approach that learns the image changes induced by motion. Its geometry-bridge connects motion-corrupted and motion-free Feldkamp-Davis-Kress (FDK) reconstructed images of the same source volume through progressively reduced simulated motion. The forward projector's geometry derivative supplies analytic velocity targets along this path. A plug-and-play loop encompasses the learned image updates together with spline-based pose estimation, conjugate-gradient data consistency, and image total-variation regularization. Both the refined image volume and the FDK reconstructed image volume at the estimated poses are evaluated. On simulated 360-view scans from 30 held-out CQ500 patients with nominal per-component motion amplitudes within 10 mm / 10 degrees, the framework achieved state-of-the-art image reconstruction quality and motion accuracy in comparison with other methos such as learned autofocus and diffusion-based joint reconstruction. Mean peak signal-to-noise ratio (PSNR) reached 37.1 dB and mean detector-plane reprojection error (RPE) was 0.27 mm. With matched endpoints at the inference settings, the geometry bridge improved PSNR by 1.6 dB and reduced RPE by 33% relative to image-linear training. With 50 prior updates and coarse-to-fine motion estimation, total processing time averaged 9.1 minutes per patient on an RTX A6000.

Results and benchmarks

Rigid motion of a patient head during head cone-beam CT (CBCT) scan can degrade image quality and complicate recovery of accurate anatomical structures from the measured projections.

Implementation

No direct implementation yet

Maintained implementation evidence is not confirmed for this paper yet.

Use the implementation status and reproduction sections for the current action plan.

Implementation evidence summary
Confidence: low

Recommendation evidence is currently too limited for a maintained-repo choice. Use Implementation Status and Reproduction Path for a practical baseline plan.

Reproduction risks
  • Estimate is based on paper-only reproduction flow

Reproduction readiness

Time to first repro: days
Last checked: Nov 25, 2026

No repo

No verified implementation available

  • No maintained repository has been identified for this paper. Check adjacent implementations or HF artifacts below.

Hardware requirements

  • With 50 prior updates and coarse-to-fine motion estimation, total processing time averaged 9.1 minutes per patient on an RTX A6000.

Framework baselines

Repositories and ecosystem

No additional verified repositories beyond the primary recommendation.

Hugging Face artifacts

No trustworthy direct or curated related Hugging Face artifacts were found yet. Use targeted searches to quickly locate candidate models, datasets, and demos.

Tip: start with models, then check datasets and spaces if you need evaluation data or demos.

Research context

Tasks

None detected

Methods

Diffusion

Domains

Computer vision

Evaluation and human feedback data

Open this paper in HFEPX to review benchmark signals, evaluation modes, and human-feedback protocol context.

Open in HFEPX
Explore similar papers

Jump to Paper2Code search queries derived from this paper's research context.