Generalize Then Personalize: Wearable-Based Heart Rate Forecasting Under Scarce Ruck-March Data
No concrete benchmark grounding is available yet. Treat the page as context or an implementation starting point only.
Abstract
Domain fit: AI-adjacent · Paper appears method- or tooling-adjacent to AI workflows with partial ecosystem coverage.
Heart rate (HR) forecasting may provide advance information about near-future cardiovascular response, potentially supporting physiological monitoring and workload-management decisions during ruck marching. However, robust model development is constrained by the difficulty of collecting large-scale ruck-march datasets, creating a scarce-data problem in which models must generalize across participants while adapting to individuals from limited personal data. To address this problem, we benchmark population-only training (POT), personalized-from-scratch training (PFST), and population-pretrained fine-tuning (PPFT) for HR forecasting during loaded ruck marching using data from eight active-duty U.S. Army medics across thirteen sessions. LSTM, Attention-LSTM, and CNN-LSTM backbones were evaluated against a persistence baseline at 30 s and 60 s horizons. Across all neural architectures and horizons, PPFT yielded lower mean MAE, RMSE, and endpoint MAE than both POT and PFST. Participant-level paired analysis after averaging across three training seeds showed that, relative to PFST, PPFT reduced trajectory MAE by 2.22-4.30 bpm and endpoint MAE by 1.24-2.88 bpm. All six trajectory-MAE comparisons remained significant after Holm adjustment ($p_{adj}$ = 0.0469), while four of six endpoint-MAE comparisons remained significant after adjustment. At 30 s, persistence achieved the lowest MAE (3.555 $\pm$ 1.274 bpm), while CNN-LSTM PPFT achieved the lowest RMSE (4.669 $\pm$ 1.916 bpm); LSTM PPFT achieved the lowest endpoint MAE (5.093 $\pm$ 2.365 bpm). At 60 s, Attention-LSTM PPFT achieved the lowest MAE (5.573 $\pm$ 1.939 bpm) and RMSE (7.134 $\pm$ 2.260 bpm), while CNN-LSTM PPFT achieved the lowest endpoint MAE (7.553 $\pm$ 2.357 bpm). These results suggest that population pretraining followed by participant-specific fine-tuning may provide a practical strategy for scarce-data wearable HR forecasting.
Results and benchmarks
Heart rate (HR) forecasting may provide advance information about near-future cardiovascular response, potentially supporting physiological monitoring and workload-management decisions during ruck marching.
Implementation
No direct implementation yet
Maintained implementation evidence is not confirmed for this paper yet.
Use the implementation status and reproduction sections for the current action plan.
No verified maintained repo yet
There is no verified maintained implementation yet. Use this baseline plan to decide whether to prototype now or defer.
- No direct maintained implementation was found. Use the paper PDF and citation graph to design a baseline reproduction.
- Track assumptions and missing details in an experiment log before coding.
Time to first repro: a few days
Recommendation evidence is currently too limited for a maintained-repo choice. Use Implementation Status and Reproduction Path for a practical baseline plan.
- Estimate is based on paper-only reproduction flow
Reproduction readiness
No repo
No verified implementation available
- No maintained repository has been identified for this paper. Check adjacent implementations or HF artifacts below.
Hardware requirements
- Expect multi-day setup/compute for meaningful reproduction based on current guidance.
Validation caveat
Framework baselines
- Hugging Face Transformers training guide
Modern transformer training baseline.
- PyTorch nn.Transformer docs
Reference transformer building block implementation.
Hugging Face artifacts
No trustworthy direct or curated related Hugging Face artifacts were found yet. Use targeted searches to quickly locate candidate models, datasets, and demos.
Datasets
Tip: start with models, then check datasets and spaces if you need evaluation data or demos.
Research context
Tasks
None detected
Methods
Transformer
Domains
None detected
Open this paper in HFEPX to review benchmark signals, evaluation modes, and human-feedback protocol context.
Open in HFEPXJump to Paper2Code search queries derived from this paper's research context.