Skip to content
OpenTrain AIFor AI Companies

CTLink: A Text-Prompted Segmentation Model for Linking Radiology Report Findings to 3D Chest CT Scans

Mohammed Baharoon, Sung Eun Kim, Mahmoud Hussain Alabbad, Lucas Bijnens, Ali Piracha +31 morePublished Nov 23, 2026
arXiv PDF
Researcher verdict
Context only
Use as context only
Benchmark evidence
Missing
Not verified yet
Time to first repro
A few days
Plan setup time
Risk flags
2
Review before use

Abstract

Domain fit: AI-adjacent · Paper appears method- or tooling-adjacent to AI workflows with partial ecosystem coverage.

Radiology reports describe findings in text only, without visually marking them on the scan, so readers cannot directly see which abnormality each reported finding refers to. We introduce CTLink, a text-prompted 3D segmentation model that segments findings described in a chest CT report. CTLink was trained on 4123 noncontrast chest CT scans with 9547 segmented report findings, including ReXGroundingCTv2, a newly annotated dataset of 1134 scans and 1895 findings with every instance of each finding segmented. On the 200 ReXGroundingCT validation scans, CTLink achieved a hit rate of 0.816, an instance F1 score of 0.456, and a mean Dice score of 0.400, compared with 0.533, 0.175, and 0.234 for VoxTell, a publicly available text-prompted segmentation model (P < .001 for all). On the test set of the MICCAI 2026 ReXGrounding challenge, an ensemble of seven CTLink models achieved the highest hit rate (0.782) and instance F1 score (0.386) of all 48 participating teams. On 50 test scans segmented twice by independent radiologists, CTLink matched or exceeded inter-rater agreement. Diffuse non-focal findings remained the main limitation, partly because their extent is outlined inconsistently even between radiologists. The CTLink model weights are available at https://huggingface.co/rajpurkarlab/CTLink, and the dataset at https://huggingface.co/datasets/rajpurkarlab/ReXGroundingCT.

Results and benchmarks

Freshness tier: warm
Radiology reports describe findings in text only, without visually marking them on the scan, so readers cannot directly see which abnormality each reported finding refers to.

Implementation

No direct implementation yet

Maintained implementation evidence is not confirmed for this paper yet.

Use the implementation status and reproduction sections for the current action plan.

Implementation evidence summary
Confidence: low

No direct maintained repository implementation was found, but paper-linked Hugging Face artifacts are available.

Reproduction risks
  • Estimate assumes artifact-level reproduction; full training reproduction may require additional paper details.

Reproduction readiness

Time to first repro: days
Last checked: Nov 24, 2026

No repo

No verified implementation available

  • No maintained repository has been identified for this paper. Check adjacent implementations or HF artifacts below.

Hardware requirements

  • Expect multi-day setup/compute for meaningful reproduction based on current guidance.

Hugging Face artifacts

Spaces

No trustworthy spaces matches right now.

Search spaces on Hugging Face

Research context

Tasks

None detected

Methods

None detected

Domains

Computer vision

Evaluation and human feedback data

Open this paper in HFEPX to review benchmark signals, evaluation modes, and human-feedback protocol context.

Open in HFEPX
Explore similar papers

Jump to Paper2Code search queries derived from this paper's research context.