Skip to content
OpenTrain AIFor AI Companies

Calibration of Neuromusculoskeletal Models Using Differentiable Physics: Recommendations for Improving Model Accuracy

Philip Sanderink, Yingfan Zhou, Shuzhen Luo, Cheng FangPublished Nov 25, 2026
arXiv PDF
Researcher verdict
Context only
Use as context only
Benchmark evidence
Missing
Not verified yet
Time to first repro
A few hours
Fast first run
Risk flags
1
Review before use

No concrete benchmark grounding is available yet. Treat the page as context or an implementation starting point only.

Abstract

Domain fit: Niche / domain-specific · No strong AI-core implementation/artifact signals were detected from current providers.

Differentiable physics has shown potential to usher in a new paradigm in human neuromusculoskeletal (NMS) model calibration. Early results from pioneering works have demonstrated that auto-differentiable NMS models can greatly reduce NMS model calibration time while achieving comparable accuracy compared to traditional calibration methods. The efficient gradient-based optimizers have enabled calibration of increasingly sophisticated human models with a large number of parameters, which seek to narrow the gap between simulation and reality. Several modules have been evaluated separately in different studies, but have never been directly compared within the same study. In this work, these modules are compared on the same differentiable upper limb model with a 3-DoF shoulder, a 2-DoF elbow, and 11 superficial and 5 deep muscles in the calibration to find an optimal pipeline for improving model accuracy. The considered modules include muscle synergy, learnable bone parameters, optimizable geometry of wrap objects, and constraint torque of the differentiable arm model. To evaluate the effect and interplay between the modules on calibration accuracy, one or more modules were used in each of 16 calibration configurations, which were compared in terms of the error between two joint torques calculated by the forward and inverse dynamics with the calibrated model on 9 distinctive testing movements across 4 subjects. Results showed that torque loss was reduced by 23.6% on average using muscle synergy extrapolation to estimate deep muscle activities, and by 10.9% on average through bone dynamic parameter optimization, which are both recommended to be incorporated in the calibration.

Results and benchmarks

Differentiable physics has shown potential to usher in a new paradigm in human neuromusculoskeletal (NMS) model calibration.

Implementation

No direct implementation yet

Maintained implementation evidence is not confirmed for this paper yet.

Use the implementation status and reproduction sections for the current action plan.

Implementation evidence summary
Confidence: low

This is primarily a method paper. Reproduce it within a maintained framework baseline instead of chasing paper-specific repos.

Reproduction risks
  • No maintained paper-verified implementation is currently available

Reproduction readiness

Time to first repro: hours
Last checked: Nov 27, 2026

No repo

No verified implementation available

  • No maintained repository has been identified for this paper. Check adjacent implementations or HF artifacts below.

Hugging Face artifacts

No trustworthy direct or curated related Hugging Face artifacts were found yet. Use targeted searches to quickly locate candidate models, datasets, and demos.

Tip: start with models, then check datasets and spaces if you need evaluation data or demos.

Research context

Tasks

Scientific computing

Methods

None detected

Domains

None detected

Evaluation and human feedback data

Open this paper in HFEPX to review benchmark signals, evaluation modes, and human-feedback protocol context.

Open in HFEPX
Explore similar papers

Jump to Paper2Code search queries derived from this paper's research context.