Skip to content
OpenTrain AIFor AI Companies

Acoustic Respiratory Phase Detection on Mobile Devices

Julian Szymanski, Tomasz Sankowski, Piotr Sulewski, Iwo Czartowski, Javier Medina QueroPublished Nov 12, 2026
arXiv PDF
Researcher verdict
Context only
Use as context only
Benchmark evidence
Thin evidence
Verify before relying
Time to first repro
A few days
Plan setup time
Risk flags
2
Review before use

Some benchmark signal exists in the extracted evidence, but it is not structured strongly enough yet for a confident benchmark decision.

Abstract

Domain fit: AI-adjacent · Paper appears method- or tooling-adjacent to AI workflows with partial ecosystem coverage.

Breathing monitoring is important for well-being, stress regulation, and guided breathing exercises, yet existing approaches often rely on contact-based sensors or controlled environments. This paper presents a non-invasive framework for respiratory phase detection using acoustic signals recorded on commodity smartphones. The proposed hybrid CNN-Transformer architecture combines local spectral feature extraction with long-range temporal modeling to capture the cyclic structure of breathing. The model is evaluated using a Leave-One-Subject-Out (LOSO) protocol on the Foundation Dataset and on an independent unseen test set comprising over 1300 breathing cycles and 2 hours of continuous recordings. The proposed 3-class formulation achieves 72.85% frame-level accuracy and 96.6% cycle-level exhalation detection efficiency in the LOSO evaluation, while achieving 76.94% frame-level accuracy, a Cohen's Kappa score of 0.65, and 99.2% cycle-level exhalation detection efficiency on the unseen test set. Results suggest that accurate respiratory monitoring may be achievable under data-constrained conditions, indicating that appropriate temporal modeling can learn transferable respiratory representations and generalize to previously unseen participants. An end-to-end ONNX deployment pipeline enables privacy-preserving on-device inference with latency below 20 ms, supporting real-time monitoring on mobile and wearable devices.

Results and benchmarks

Breathing monitoring is important for well-being, stress regulation, and guided breathing exercises, yet existing approaches often rely on contact-based sensors or controlled environments.

Implementation

No direct implementation yet

Maintained implementation evidence is not confirmed for this paper yet.

Use the implementation status and reproduction sections for the current action plan.

Implementation evidence summary
Confidence: low

Recommendation evidence is currently too limited for a maintained-repo choice. Use Implementation Status and Reproduction Path for a practical baseline plan.

Reproduction risks
  • Estimate is based on paper-only reproduction flow

Reproduction readiness

Time to first repro: days
Last checked: Nov 25, 2026

No repo

No verified implementation available

  • No maintained repository has been identified for this paper. Check adjacent implementations or HF artifacts below.

Hardware requirements

  • Expect multi-day setup/compute for meaningful reproduction based on current guidance.

Framework baselines

Hugging Face artifacts

No trustworthy direct or curated related Hugging Face artifacts were found yet. Use targeted searches to quickly locate candidate models, datasets, and demos.

Tip: start with models, then check datasets and spaces if you need evaluation data or demos.

Research context

Tasks

Transformer, Detection

Methods

Transformer

Domains

None detected

Evaluation and human feedback data

Open this paper in HFEPX to review benchmark signals, evaluation modes, and human-feedback protocol context.

Open in HFEPX
Explore similar papers

Jump to Paper2Code search queries derived from this paper's research context.