A Stage-Wise Explainable Pipeline for Arteriolar-to-Venular Ratio Estimation and Retinopathy Screening
Abstract
Domain fit: Niche / domain-specific · No strong AI-core implementation/artifact signals were detected from current providers.
The arteriolar-to-venular diameter ratio (AVR) is a clinically motivated marker of retinal vascular health. We present a five-stage pipeline for AVR estimation and exploratory retinopathy screening from fundus images, with inspectable intermediate outputs at each stage. The pipeline combines vessel and artery-vein masks, optic-disc localization, vessel-calibre estimation using a minimal-chord boundary walk, and AVR computation from dominant arterial and venular branches. An explicit threshold-based rule produces the screening decision, enabling errors to be traced to individual processing stages. On an exploratory cohort of 30 HRF images, we report 96.7% accuracy, an F1-score of 0.968 and ROC-AUC of 0.978. Ablation studies and an exploratory comparison with VascX examine the effects of vessel pairing, calibre measurement and aggregation. Interpretation is limited by the small cohort, proxy disease labels and absence of independent reference calibre measurements. The pipeline provides a transparent framework for investigating retinal vascular biomarkers, with further validation needed on larger, clinically graded cohorts.
Results and benchmarks
The arteriolar-to-venular diameter ratio (AVR) is a clinically motivated marker of retinal vascular health.
| Task | Dataset | Metric | Value | Source |
|---|---|---|---|---|
| Arteriolar-to-venular Ratio Estimation Retinopathy Screening | VascX | AUC. | 0.938 | paper-derived |
| Arteriolar-to-venular Ratio Estimation Retinopathy Screening | Proposed | AUC. | 0.978 | paper-derived |
Audit each benchmark finding before selecting an implementation path.
Implementation
No direct implementation yet
Maintained implementation evidence is not confirmed for this paper yet.
Use the implementation status and reproduction sections for the current action plan.
No verified maintained repo yet
There is no verified maintained implementation yet. Use this baseline plan to decide whether to prototype now or defer.
- No direct maintained implementation was found. Use the paper PDF and citation graph to design a baseline reproduction.
- Track assumptions and missing details in an experiment log before coding.
Time to first repro: a few days
Recommendation evidence is currently too limited for a maintained-repo choice. Use Implementation Status and Reproduction Path for a practical baseline plan.
- Estimate is based on paper-only reproduction flow
Reproduction readiness
No repo
No verified implementation available
- No maintained repository has been identified for this paper. Check adjacent implementations or HF artifacts below.
Hardware requirements
- Expect multi-day setup/compute for meaningful reproduction based on current guidance.
Hugging Face artifacts
No trustworthy direct or curated related Hugging Face artifacts were found yet. Use targeted searches to quickly locate candidate models, datasets, and demos.
Models
Datasets
Spaces
Tip: start with models, then check datasets and spaces if you need evaluation data or demos.
Research context
Tasks
Arteriolar-to-venular Ratio Estimation Retinopathy Screening
Methods
None detected
Domains
None detected
Open this paper in HFEPX to review benchmark signals, evaluation modes, and human-feedback protocol context.