Skip to content
← Back to explorer

Towards single-shot coherent imaging via overlap-free ptychography

Oliver Hoidn, Aashwin Mishra, Steven Henke, Albert Vong, Matthew Seaberg · Feb 24, 2026 · Citations: 0

Abstract

Ptychographic imaging at synchrotron and XFEL sources requires dense overlapping scans, limiting throughput and increasing dose. Extending coherent diffractive imaging to overlap-free operation on extended samples remains an open problem. Here, we extend PtychoPINN (O. Hoidn \emph{et al.}, \emph{Scientific Reports} \textbf{13}, 22789, 2023) to deliver \emph{overlap-free, single-shot} reconstructions in a Fresnel coherent diffraction imaging (CDI) geometry while also accelerating conventional multi-shot ptychography. The framework couples a differentiable forward model of coherent scattering with a Poisson photon-counting likelihood; real-space overlap enters as a tunable parameter via coordinate-based grouping rather than a hard requirement. On synthetic benchmarks, reconstructions remain accurate at low counts ($\sim\!10^4$ photons/frame), and overlap-free single-shot reconstruction with an experimental probe reaches amplitude structural similarity (SSIM) 0.904, compared with 0.968 for overlap-constrained reconstruction. Against a data-saturated supervised model with the same backbone (16,384 training images), PtychoPINN achieves higher SSIM with only 1,024 images and generalizes to unseen illumination profiles. Per-graphics processing unit (GPU) throughput is approximately $40\times$ that of least-squares maximum-likelihood (LSQ-ML) reconstruction at matched $128\times128$ resolution. These results, validated on experimental data from the Advanced Photon Source and the Linac Coherent Light Source, unify single-exposure Fresnel CDI and overlapped ptychography within one framework, supporting dose-efficient, high-throughput imaging at modern light sources.

Human Data Lens

  • Uses human feedback: No
  • Feedback types: None
  • Rater population: Unknown
  • Unit of annotation: Unknown
  • Expertise required: General

Evaluation Lens

  • Evaluation modes: Automatic Metrics
  • Agentic eval: None
  • Quality controls: Not reported
  • Confidence: 0.35
  • Flags: low_signal, possible_false_positive

Research Summary

Contribution Summary

  • Ptychographic imaging at synchrotron and XFEL sources requires dense overlapping scans, limiting throughput and increasing dose.
  • Extending coherent diffractive imaging to overlap-free operation on extended samples remains an open problem.
  • Here, we extend PtychoPINN (O.

Why It Matters For Eval

  • On synthetic benchmarks, reconstructions remain accurate at low counts ($\sim\!10^4$ photons/frame), and overlap-free single-shot reconstruction with an experimental probe reaches amplitude structural similarity (SSIM) 0.904, compared with

Related Papers