Skip to content
OpenTrain AIFor AI Companies

RefineFormer3D: Efficient 3D Medical Image Segmentation via Adaptive Multi-Scale Transformer with Cross Attention Fusion

Kavyansh Tyagi, Vishwas Rathi, Puneet GoyalPublished Feb 18, 2026
arXiv PDF
Researcher verdict
Context only
Use as context only
Benchmark evidence
Thin evidence
Verify before relying
Time to first repro
A few days
Plan setup time
Risk flags
2
Review before use

Abstract

Domain fit: AI-adjacent · Paper appears method- or tooling-adjacent to AI workflows with partial ecosystem coverage.

Accurate and computationally efficient 3D medical image segmentation remains a critical challenge in clinical workflows. Transformer-based architectures often demonstrate superior global contextual modeling but at the expense of excessive parameter counts and memory demands, restricting their clinical deployment. We propose RefineFormer3D, a lightweight hierarchical transformer architecture that balances segmentation accuracy and computational efficiency for volumetric medical imaging. The architecture integrates three key components: (i) GhostConv3D-based patch embedding for efficient feature extraction with minimal redundancy, (ii) MixFFN3D module with low-rank projections and depthwise convolutions for parameter-efficient feature extraction, and (iii) a cross-attention fusion decoder enabling adaptive multi-scale skip connection integration. RefineFormer3D contains only 2.94M parameters, substantially fewer than contemporary transformer-based methods. Extensive experiments on ACDC and BraTS benchmarks demonstrate that RefineFormer3D achieves 93.44\% and 85.9\% average Dice scores respectively, outperforming or matching state-of-the-art methods while requiring significantly fewer parameters. Furthermore, the model achieves fast inference (8.35 ms per volume on GPU) with low memory requirements, supporting deployment in resource-constrained clinical environments. These results establish RefineFormer3D as an effective and scalable solution for practical 3D medical image segmentation.

Results and benchmarks

Freshness tier: hot
Accurate and computationally efficient 3D medical image segmentation remains a critical challenge in clinical workflows.
Task Dataset Metric Value Source
Transformer UNETR Mem † 3.3 paper-derived

Audit each benchmark finding before selecting an implementation path. Evidence refs map to the disclosure below.

Implementation

No direct implementation yet

Maintained implementation evidence is not confirmed for this paper yet.

Use the implementation status and reproduction sections for the current action plan.

Implementation evidence summary
Confidence: low

Recommendation evidence is currently too limited for a maintained-repo choice. Use Implementation Status and Reproduction Path for a practical baseline plan.

Reproduction risks
  • Estimate is based on paper-only reproduction flow

Reproduction readiness

Time to first repro: days
Last checked: Sep 5, 2026

No repo

No verified implementation available

  • No maintained repository has been identified for this paper. Check adjacent implementations or HF artifacts below.

Hardware requirements

  • Expect multi-day setup/compute for meaningful reproduction based on current guidance.

Framework baselines

Hugging Face artifacts

No trustworthy direct or curated related Hugging Face artifacts were found yet. Use targeted searches to quickly locate candidate models, datasets, and demos.

Tip: start with models, then check datasets and spaces if you need evaluation data or demos.

Research context

Tasks

Transformer

Methods

Transformer, LoRA / Parameter-efficient tuning

Domains

Computer vision

Evaluation and human feedback data

Open this paper in HFEPX to review benchmark signals, evaluation modes, and human-feedback protocol context.

Open in HFEPX
Explore similar papers

Jump to Paper2Code search queries derived from this paper's research context.