Skip to content
OpenTrain AIFor AI Companies

Polaffini: A feature-based approach for robust affine and polyaffine image registration

Antoine Legouhy, Cosimo Campo, Ross Callaghan, Hojjat Azadbakht, Hui ZhangPublished Feb 19, 2026
arXiv PDF
Researcher verdict
Context only
Use as context only
Benchmark evidence
Missing
Not verified yet
Time to first repro
A few days
Plan setup time
Risk flags
2
Review before use

Abstract

Domain fit: AI-adjacent · Paper appears method- or tooling-adjacent to AI workflows with partial ecosystem coverage.

In this work we present Polaffini, a robust and versatile framework for anatomically grounded registration. Medical image registration is dominated by intensity-based registration methods that rely on surrogate measures of alignment quality. In contrast, feature-based approaches that operate by identifying explicit anatomical correspondences, while more desirable in theory, have largely fallen out of favor due to the challenges of reliably extracting features. However, such challenges are now significantly overcome thanks to recent advances in deep learning, which provide pre-trained segmentation models capable of instantly delivering reliable, fine-grained anatomical delineations. We aim to demonstrate that these advances can be leveraged to create new anatomically-grounded image registration algorithms. To this end, we propose Polaffini, which obtains, from these segmented regions, anatomically grounded feature points with 1-to-1 correspondence in a particularly simple way: extracting their centroids. These enable efficient global and local affine matching via closed-form solutions. Those are used to produce an overall transformation ranging from affine to polyaffine with tunable smoothness. Polyaffine transformations can have many more degrees of freedom than affine ones allowing for finer alignment, and their embedding in the log-Euclidean framework ensures diffeomorphic properties. Polaffini has applications both for standalone registration and as pre-alignment for subsequent non-linear registration, and we evaluate it against popular intensity-based registration techniques. Results demonstrate that Polaffini outperforms competing methods in terms of structural alignment and provides improved initialisation for downstream non-linear registration. Polaffini is fast, robust, and accurate, making it particularly well-suited for integration into medical image processing pipelines.

Results and benchmarks

Freshness tier: warm
In this work we present Polaffini, a robust and versatile framework for anatomically grounded registration.

Implementation

No direct implementation yet

Maintained implementation evidence is not confirmed for this paper yet.

Use the implementation status and reproduction sections for the current action plan.

Implementation evidence summary
Confidence: low

Recommendation evidence is currently too limited for a maintained-repo choice. Use Implementation Status and Reproduction Path for a practical baseline plan.

Reproduction risks
  • Estimate is based on paper-only reproduction flow

Reproduction readiness

Time to first repro: days
Last checked: Aug 24, 2026

No repo

No verified implementation available

  • No maintained repository has been identified for this paper. Check adjacent implementations or HF artifacts below.

Hardware requirements

  • Expect multi-day setup/compute for meaningful reproduction based on current guidance.

Hugging Face artifacts

No trustworthy direct or curated related Hugging Face artifacts were found yet. Use targeted searches to quickly locate candidate models, datasets, and demos.

Tip: start with models, then check datasets and spaces if you need evaluation data or demos.

Research context

Tasks

None detected

Methods

None detected

Domains

Computer vision

Evaluation and human feedback data

Open this paper in HFEPX to review benchmark signals, evaluation modes, and human-feedback protocol context.

Open in HFEPX
Explore similar papers

Jump to Paper2Code search queries derived from this paper's research context.