Increasing the Energy-Efficiency of Wearables Using Low-Precision Posit Arithmetic with PHEE

David Mallasén, Pasquale Davide Schiavone, Alberto A. Del Barrio, Manuel Prieto-Matias, David AtienzaPublished Jan 30, 2025
arXiv PDF
Researcher verdict
Context only
Use as context only
Benchmark evidence
Missing
Not verified yet
Time to first repro
A few days
Plan setup time
Risk flags
2
Review before use

Abstract

Domain fit: Niche / domain-specific · No strong AI-core implementation/artifact signals were detected from current providers.

Wearable biomedical devices are increasingly being used for continuous patient health monitoring, enabling real-time insights and extended data collection without the need for prolonged hospital stays. These devices must be energy efficient to minimize battery size, improve comfort, and reduce recharging intervals. This paper investigates the use of specialized low-precision arithmetic formats to enhance the energy efficiency of biomedical wearables. Specifically, we explore posit arithmetic, a floating-point-like representation, in two key applications: cough detection for chronic cough monitoring and R peak detection in ECG analysis. Simulations reveal that 16-bit posits can replace 32-bit IEEE 754 floating point numbers with minimal accuracy loss in cough detection. For R peak detection, posit arithmetic achieves satisfactory accuracy with as few as 10 or 8 bits, compared to the 16-bit requirement for floating-point formats. To further this exploration, we introduce PHEE, a modular and extensible architecture that integrates the Coprosit posit coprocessor within a RISC-V-based system. Using the X-HEEP framework, PHEE seamlessly incorporates posit arithmetic, demonstrating reduced hardware area and power consumption compared to a floating-point counterpart system. Post-synthesis results targeting 16nm TSMC technology show that the posit hardware targeting these biomedical applications can be 38% smaller and consume up to 54% less energy at the functional unit level, with no performance compromise. These findings establish the potential of low-precision posit arithmetic to significantly improve the energy efficiency of wearable biomedical devices.

Results and benchmarks

Freshness tier: cold
Wearable biomedical devices are increasingly being used for continuous patient health monitoring, enabling real-time insights and extended data collection without the need for prolonged hospital stays.

Implementation

No direct implementation yet

Maintained implementation evidence is not confirmed for this paper yet.

Use the implementation status and reproduction sections for the current action plan.

Implementation evidence summary
Confidence: low

Recommendation evidence is currently too limited for a maintained-repo choice. Use Implementation Status and Reproduction Path for a practical baseline plan.

Reproduction risks
  • Estimate is based on paper-only reproduction flow

Reproduction readiness

Time to first repro: days
Last checked: Aug 25, 2026

No repo

No verified implementation available

  • No maintained repository has been identified for this paper. Check adjacent implementations or HF artifacts below.

Hardware requirements

  • Expect multi-day setup/compute for meaningful reproduction based on current guidance.

Hugging Face artifacts

No trustworthy direct or curated related Hugging Face artifacts were found yet. Use targeted searches to quickly locate candidate models, datasets, and demos.

Tip: start with models, then check datasets and spaces if you need evaluation data or demos.

Research context

Tasks

Scientific computing

Methods

None detected

Domains

None detected

Evaluation and human feedback data

Open this paper in HFEPX to review benchmark signals, evaluation modes, and human-feedback protocol context.

Open in HFEPX
Explore similar papers

Jump to Paper2Code search queries derived from this paper's research context.